Tcp Udp Setup
This object configures the transport endpoint used for meter communication over an IP network. It links the listening port to IP settings and defines connection limits.
When to use it
Use it when setting the port on which a meter accepts remote connections and deciding how long idle TCP sessions can remain open.
Attributes
1. Logical name
The OBIS code that identifies this object instance in the meter. Use it to distinguish this instance from other objects of the same class.
2. Port
Sets the TCP or UDP listening port for meter communication, or the UDP endpoint used by CoAP.
3. IP reference
Identifies the IPv4 or IPv6 setup object that supplies the underlying network configuration.
See IPv4 setup and IPv6 setup for the underlying interface settings.
4. Maximum segment size
Advertises the maximum TCP receive segment size to the other endpoint during connection establishment.
5. Maximum simultaneous connections
Limits how many transport connections the meter can support at once.
6. Inactivity timeout
Sets how many seconds without received traffic cause an idle TCP connection to close. Zero disables this timeout.
Actions