Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Node
  3. M-Bus Diagnostics
By Gurux Documentation , 10 November, 2026

M-Bus diagnostics

Shows the health and traffic statistics of an M-Bus communication link.

When to use it

For example, compare received signal strength and failed frames when investigating missed wireless meter readings.

Attributes

1. Logical name

Identifies this object instance by its six-part OBIS code. Use it to distinguish this object from other objects of the same class.

2. Received signal strength

Shows the strength of the last received wireless M-Bus signal in dBm. This applies to bidirectional wireless communication.

3. Channel Id

Identifies the channel on which communication is taking place.

4. Link status

Reports the current condition of the communication link.

5. Broadcast frames

Records broadcast reception counts separately for each client identifier, together with the time of the last received frame.

6. Transmissions

Counts frames transmitted by the interface.

7. Received frames

Counts received frames that passed their checksum check.

8. Failed received frames

Counts received frames that failed their checksum check.

9. Capture time

Identifies the most recently changed diagnostic attribute and records when it changed.

  • Log in or register to post comments
  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv6 setup
  • Image-Übertragung
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Utility tables
  • Manufacturer custom objects
  • Account
  • Arbitrator
  • Array manager
  • Charge
  • CoAP diagnostics
  • CoAP setup
  • Communication port protection
  • Credit
  • Data protection
  • Function control
  • G3-PLC 6LoWPAN setup
  • G3-PLC MAC layer counters
  • G3-PLC MAC setup
  • LLC SSCS setup
  • LTE monitoring
  • M-Bus diagnostics
  • M-Bus port setup
  • Network time setup
  • Parameter monitor
  • PRIME application identification
  • PRIME MAC counters
  • PRIME MAC functional parameters
  • PRIME MAC setup
  • PRIME network administration data
  • PRIME physical layer counters
  • S-FSK active initiator
  • S-FSK MAC counters
  • S-FSK physical and MAC setup
  • S-FSK reporting system list
  • S-FSK synchronisation timeouts
  • Schedule
  • Short name association
  • STS payment token settings
  • Tariff plan
  • Token gateway
  • Twisted pair setup
  • Wireless mode Q channel
  • IPv4 setup
  • Register activation

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Bank Mandiri KC Sukamara call/wa 0813-627-9539.
  • Dollar Mart Money Changer ☎️/Wa 083150344509
  • PT.Srikandi Utama Valusindo ☎️/Wa 083150344509
  • Bank Mandiri Kuala Kapuas call/wa 0813-627-9539.
  • PT Yonglin Valas Jaya Telp/Wa 083831618807
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin