By Administrator , 23 January, 2018

Profile generic

A profile stores rows of captured object values. Its capture list defines the columns, while capture and sorting settings control how rows are collected and retained.

When to use it

Use it to read a load profile containing timestamps, energy readings and status values.

Attributes

1. Logical name

Identifies this object instance using its six-part OBIS code. Use it to distinguish this object from other instances of the same class.

2. Buffer

Contains the stored rows of captured values.

Read Capture objects before decoding the buffer so the column definitions are available.

3. Capture objects

Defines the columns by listing each source object class, logical name, attribute index and data index. The data index can select an element of a structured attribute; zero selects the complete attribute.

4. Capture period

Sets the automatic capture interval in seconds. A value of zero disables periodic capture.

5. Sort method

Selects the ordering and retention rule, such as first-in first-out or sorting by a captured value.

6. Sort object

Identifies the sorting key by object class, logical name, attribute index and data index.

A captured Clock value can provide the time-based sorting key when the profile is configured that way.

7. Entries in use

Shows the number of rows currently stored.

8. Profile entries

Defines the maximum number of rows the profile can hold.

Versions

Versions 0 and 1 use the same attribute indexes and names. Use the object version and the device-supported access selections when retrieving profile rows.

Actions

1. Reset

Clears the buffer.

2. Capture

Captures values from the capture object list to the buffer.

Reading data

Data can be read in three different ways from profile generic objects.

  • Read all data
  • Read by range (between start and end time)
  • Read by entry (using index and count)

Note!
You need to read or update Capture objects before reading the buffer.

Read by range might cause problems with some meters. Some meters expect that start and end time are rounded to the nearest hour and they can't handle the seconds or minutes if they are not equal to zero.
Some meters are sending rows where the timestamp is higher than start time and some meters are sending rows where the timestamp is equal to start time.

Read by range is problematic, because data must loop throught to find where data starts and where it ends. Also amount of rows is not known before data is filtered.

  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv6 setup
  • Image-Übertragung
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Utility tables
  • Manufacturer custom objects
  • Account
  • Arbitrator
  • Array manager
  • Charge
  • CoAP diagnostics
  • CoAP setup
  • Communication port protection
  • Credit
  • Data protection
  • Function control
  • G3-PLC 6LoWPAN setup
  • G3-PLC MAC layer counters
  • G3-PLC MAC setup
  • LLC SSCS setup
  • LTE monitoring
  • M-Bus diagnostics
  • M-Bus port setup
  • Network time setup
  • Parameter monitor
  • PRIME application identification
  • PRIME MAC counters
  • PRIME MAC functional parameters
  • PRIME MAC setup
  • PRIME network administration data
  • PRIME physical layer counters
  • S-FSK active initiator
  • S-FSK MAC counters
  • S-FSK physical and MAC setup
  • S-FSK reporting system list
  • S-FSK synchronisation timeouts
  • Schedule
  • Short name association
  • STS payment token settings
  • Tariff plan
  • Token gateway
  • Twisted pair setup
  • Wireless mode Q channel
  • IPv4 setup
  • Register activation

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Travel umroh Salsa Medan & Penukaran Uang asing ☎️/Wa 083150344509
  • Pt Valas Makmur Jaya Money Changer ☎️/Wa 083150344509
  • PT.Srikandi Utama Valusindo Telp/Wa 083831618807
  • PT Yonglin Valas Jaya Telp/Wa 083831618807
  • Dollar Mart Money Changer ☎️/Wa 083150344509
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin