M-Bus Client
Represents an M-Bus device read by a DLMS meter or gateway. It links the communication port, selected data records and identity of the attached device.
When to use it
For example, configure a gateway to collect water meter readings every hour and map them to its DLMS objects.
Attributes
1. Logical name
Identifies this object instance by its six-part OBIS code. Use it to distinguish this object from other objects of the same class.
2. MBus Port Reference
Identifies the M-Bus port object used to communicate with the attached device.
3. Capture Definition
Identifies the M-Bus data records to capture using their data-information and value-information blocks.
4. Capture Period
Sets the interval between automatic data collections in seconds. A zero value disables periodic collection.
5. Primary Address
Contains the short M-Bus address used to select the attached device.
6. Identification Number
Contains the identification number reported by the attached device.
7. Manufacturer ID
Contains the manufacturer code reported in the M-Bus device identity.
8. Version
Contains the M-Bus product or device revision reported by the attached device.
9. Device Type
Identifies the type of device or measured medium, such as water, heat or gas.
10. Access Number
Contains the access number from the last M-Bus response, which helps identify successive telegrams.
11. Status
Contains status flags reported by the attached device, such as temporary or permanent errors.
12. Alarm
Contains alarm information reported by the attached device.
13. Configuration
Shows the configuration field received from the M-Bus device, including its encryption mode and number of encrypted bytes. Updated on each device readout.
14. Encryption Key Status
Reports the state of the encryption key used with the attached device.
Versions
Attribute availability depends on the object version reported by the meter (version 0: attributes 1-12; version 1: attributes 1-14). Use the version-specific descriptions above when an attribute's meaning or representation differs.
Actions
1. Slave install
Installs a unconfigured slave device.
2. Slave deinstall
De-installs the slave device.
3. Capture
Capture values.
4. Reset alarm
Reset alarm state of the M-Bus slave device.
5. Synchronize clock
Synchronize the clock of the M-Bus slave device.
6. Data send
Send data to the M-Bus slave device.
7. Set encryption key
Sets encryption key to be used with the M-Bus slave device.
8. Transfer key
Transfers an encryption key to the M-Bus slave.
.