By Gurux Documentation , 10 November, 2026

CoAP diagnostics

This object reports activity and problems in the meter's CoAP communication layers. Its counters help distinguish message delivery problems from request handling or block transfer failures.

When to use it

Use it when a CoAP connection is slow or unreliable and you need to check retries, errors or incomplete transfers.

Attributes

1. Logical name

The OBIS code that identifies this object instance in the meter. Use it to distinguish this instance from other objects of the same class.

2. Messages counter

Groups counts of sent, received and repeated messages, acknowledgements, resets and dropped messages. It also reports responses sent separately from acknowledgements and abandoned transmissions.

3. Request response counter

Groups counts of requests, successful responses and client or server errors in both directions. These counts describe application exchanges rather than retransmissions.

4. Block transfer counter

Counts block transfers that started, completed or timed out. Use it to find failures when larger messages are split into blocks.

5. Capture time

Records an attribute identifier and the time of the most recent recorded counter change or reset.

  • Log in or register to post comments
  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv6 setup
  • Image-Übertragung
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Utility tables
  • Manufacturer custom objects
  • Account
  • Arbitrator
  • Array manager
  • Charge
  • CoAP diagnostics
  • CoAP setup
  • Communication port protection
  • Credit
  • Data protection
  • Function control
  • G3-PLC 6LoWPAN setup
  • G3-PLC MAC layer counters
  • G3-PLC MAC setup
  • LLC SSCS setup
  • LTE monitoring
  • M-Bus diagnostics
  • M-Bus port setup
  • Network time setup
  • Parameter monitor
  • PRIME application identification
  • PRIME MAC counters
  • PRIME MAC functional parameters
  • PRIME MAC setup
  • PRIME network administration data
  • PRIME physical layer counters
  • S-FSK active initiator
  • S-FSK MAC counters
  • S-FSK physical and MAC setup
  • S-FSK reporting system list
  • S-FSK synchronisation timeouts
  • Schedule
  • Short name association
  • STS payment token settings
  • Tariff plan
  • Token gateway
  • Twisted pair setup
  • Wireless mode Q channel
  • IPv4 setup
  • Register activation

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • PT Yonglin Valas Jaya Telp/Wa 083831618807
  • Bank Mandiri Pulang Pisau call/wa 0813-627-9539.
  • Bank Mandiri Banjarmasin Mitra Plaza call/wa 0813-627-9539.
  • Bank Mandiri KC Tamiang Layang call/wa 0813-627-9539.
  • Bank Mandiri KC Sukamara call/wa 0813-627-9539.
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin