Compact data
Compact data stores captured values in a compact binary representation. A template describes the data types so a reader can decode the buffer without repeated type information.
When to use it
Use it to collect a fixed set of measurements while reducing the size of stored or transmitted data.
Attributes
1. Logical name
Identifies this object instance using its six-part OBIS code. Use it to distinguish this object from other instances of the same class.
2. Buffer
Contains the compact encoded captured values.
3. Capture objects
Lists the source objects, attribute indexes and optional element indexes to capture.
4. Template id
Identifies the template associated with the buffer.
5. Template description
Describes the structure and data types required to decode the buffer.
6. Capture method
Selects how captures are initiated, such as explicit capture or capture when the buffer is read.
In read-based capture, reading the buffer initiates capture. In action-based capture, the Capture action initiates it.
Versions
Attribute availability depends on the object version reported by the meter (version 0: attributes 1-6; version 1: attributes 1-6). Use the version-specific descriptions above when an attribute's meaning or representation differs.
Actions
1. Reset
Clears the buffer.
2. Capture
Saves objects defined in Capture Objects to the buffer.
Note! Italy norm UNI/TS 11291-11-2 is breaking against DLMS standard in some of Trama compatta compact data buffers. Array length (AA) is added to the buffer. This is done example in Trama compatta 7. If AA is needed, appendAA must set to 1. Values must update using compactData_getValues2 where last parameter is set to 1.