Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. General Discussion
Description

General discussion about Gurux community, forum, bugtracker, GXDN, web site, and / or products.

Image
By spuentesp , 29 March, 2018

Trying to read .dat Files from Actaris

Forums
General discussion

Hi,

i'm a software engineer specialized in front-end and middleware, so i know absolutely nothing (except from what google taught me) about smart meters, electrical metering, etc.

We have a client that needs to read dat files. As far as i know, these DAT files are converted to Excel files by a software called "Notus XLS" from Actaris. We can't open the files directly with excel. they must be converted.

for now, we have only the information in the beggining of the file, that we can read using a HEX editor:

By sluge , 29 March, 2018

StoC key

Forums
General discussion

Hello,

I can't find in Green Book mention about what key should be used to encrypt StoC for HLS.

Is it server's auth key, server's encryption key, ded-key (if used) or some other key.

In Green book I find only a note about it: "Man. Spec.". What does it means Man. Spec.?

By hakan , 27 March, 2018

Landis+Gyr DC450

Forums
General discussion

Hi,

My problem is not about dlms. But We couldn't any solution. Maybe someone can be help us.

Landis+gyr DC450 installed and Landis+Gyr meters communication on PLC(Power Line comm) with DC450.

We are trying read meter data on DC450. I am not sure But we can get PLC meters data with web service on DC450. We can't find any document about Web Service running on DC450. Is there any one read meters data from DC450? Can you suggest any document about this issue?

By iamzero5 , 17 March, 2018

Read IEC 62056-21

Forums
General discussion

Hi,

Is there a way to read meters with iec 62056-21?

By ashwinmur , 6 March, 2018

HPL PPEM24 Net Meter

Forums
General discussion

Dear Sir

we are using HPL (Indian Standard) PPEM24net Meter , we have few Question for information

How to Connect the RS232 serial to PC ?
GX director Setting for the above

we contacted the manufacture for password and they the password is 111111111111

Please help us

By PabloNimbeo , 5 March, 2018

MacOS Support?

Forums
General discussion

Is MacOS support planned for the future?

As far as I know, there are some .dll's for Windows and some .so's for Linux and arm architectures. Are there any plans for MacOS?

Thanks

By gcorbaz , 1 March, 2018

Amount of meter supported by Gurux

Forums
General discussion

Hello,

Is it possible to manage several tens of thousands of meters on the Gurux Platform ?

Regards, Guy.

By matallanas , 26 February, 2018

ZIV 5CTM - Read Parameters

Forums
General discussion

Hello, I am using Gurux.DLMS.cpp Client to read the data from a ZIV smart meter. However, I am able to read only a few objects from the meter. In addition I am not able to read even the clock, I have put the client address and the server address but it only can read a few objects.
Does anyone knows if anything else is required to read from the meter?

Thank you very much.

By Virus , 16 February, 2018

Trying readout at 9600 not 300

Forums
General discussion

Good day

I'm trying to do meter readout using 9600 Baud rate.

With 300 I just send .!?..

How do I do it at 9600?

I have tried 0x06 0x30 0x35 0x30 0x8d 0x0a
But when port is then set to 9600 I read all 0x00 0x00 0x00.

Is there a specific Readout Command for IEC before switching to DLMS?

Blessings
Herman

By Anto sujesh , 15 February, 2018

Gurux.DLMS.cpp where to start

Forums
General discussion

Hi,
Am new to DLMS programming. i need to get Voltage (V1) from the meter using Gurux.DLMS.cpp.
In GitHub i can see GuruxDLMSClientExample, GuruxDLMSPushExample, GuruxDLMSServerExample so which project i should use and where to start. i know its a very basic question. plz guide me to start it.

Am from India
Meter Information
Sprint 350
Type : E3D109
S.No : Y0517221

Pagination

  • Previous page
  • 57
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Possible memory leak in file dlms.c, getCompactArrayItem(), getCompactArrayItem2()
  • Official Gurux.DLMS.Client.Example.Net fails during High GMAC secure association (Invalid PDU), while Gurux Director connects successfully
  • gurux_dlms.GXDateTime.GXDateTime object Error in Python
  • T_APPL_DATA_LN_N1 subtest 3 fails on an LN-only server regardless of the response to a non-existing-object GET
  • Version mismatch between Gurux.DLMS 9.x and Gurux.Common/Gurux.Serial 8.x
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin