By hakan , 27 March, 2018

Landis+Gyr DC450

Forums
General discussion

Hi,

My problem is not about dlms. But We couldn't any solution. Maybe someone can be help us.

Landis+gyr DC450 installed and Landis+Gyr meters communication on PLC(Power Line comm) with DC450.

We are trying read meter data on DC450. I am not sure But we can get PLC meters data with web service on DC450. We can't find any document about Web Service running on DC450. Is there any one read meters data from DC450? Can you suggest any document about this issue?

By iamzero5 , 17 March, 2018

Read IEC 62056-21

Forums
General discussion

Hi,

Is there a way to read meters with iec 62056-21?

By ashwinmur , 6 March, 2018

HPL PPEM24 Net Meter

Forums
General discussion

Dear Sir

we are using HPL (Indian Standard) PPEM24net Meter , we have few Question for information

How to Connect the RS232 serial to PC ?
GX director Setting for the above

we contacted the manufacture for password and they the password is 111111111111

Please help us

By PabloNimbeo , 5 March, 2018

MacOS Support?

Forums
General discussion

Is MacOS support planned for the future?

As far as I know, there are some .dll's for Windows and some .so's for Linux and arm architectures. Are there any plans for MacOS?

Thanks

By gcorbaz , 1 March, 2018

Amount of meter supported by Gurux

Forums
General discussion

Hello,

Is it possible to manage several tens of thousands of meters on the Gurux Platform ?

Regards, Guy.

By matallanas , 26 February, 2018

ZIV 5CTM - Read Parameters

Forums
General discussion

Hello, I am using Gurux.DLMS.cpp Client to read the data from a ZIV smart meter. However, I am able to read only a few objects from the meter. In addition I am not able to read even the clock, I have put the client address and the server address but it only can read a few objects.
Does anyone knows if anything else is required to read from the meter?

Thank you very much.

By Virus , 16 February, 2018

Trying readout at 9600 not 300

Forums
General discussion

Good day

I'm trying to do meter readout using 9600 Baud rate.

With 300 I just send .!?..

How do I do it at 9600?

I have tried 0x06 0x30 0x35 0x30 0x8d 0x0a
But when port is then set to 9600 I read all 0x00 0x00 0x00.

Is there a specific Readout Command for IEC before switching to DLMS?

Blessings
Herman

By Anto sujesh , 15 February, 2018

Gurux.DLMS.cpp where to start

Forums
General discussion

Hi,
Am new to DLMS programming. i need to get Voltage (V1) from the meter using Gurux.DLMS.cpp.
In GitHub i can see GuruxDLMSClientExample, GuruxDLMSPushExample, GuruxDLMSServerExample so which project i should use and where to start. i know its a very basic question. plz guide me to start it.

Am from India
Meter Information
Sprint 350
Type : E3D109
S.No : Y0517221

By Virus , 19 January, 2018

Last byte of Load Profile Command

Forums
General discussion

Good day

I have command to read Load Profile, but don't know what the last byte should be.
This is for a Landis&Gyr meter. (E650)

Command:(IEC)
[Read Load Profile] 10 bytes [Date from] 6 bytes [Time from] 4 bytes [Separator] 2 bytes [Date to] 6 bytes [Time to] 4 bytes [command end] 3 bytes
[81 d2 35 82 50 2e 30 b1 28 30] [YY YY MM MM DD DD] [hh hh mm mm]
[bb 30] [YY YY MM MM DD DD] [hh hh mm mm] [a9 03 ??] <- this last byte is unknown.

Is there a formula for calculating this byte?
The value ranges between 20-29, a0-a9.

By Valendil1403 , 4 January, 2018

Setting of EMI metering

Forums
General discussion

Hi

Its is first time setting up a EMI metering (LZQJ-XC).
Any tips on the way?

How to we select current transformer 5A/300A

We want to use RS485 DLMS and convert it to IEC61850 protocol. Using Kalkitech gatway, never used it before.

Thanks,

Pagination

  • Previous page
  • 57
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 06/15/2026 - 08:52
    gurux.dlms.c 9.0.2606.1501
  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15