Image
By FredC , 10 June, 2019

Invocation Counter with HLS security Question

Forums
General discussion

Hi,

By Amiya , 29 May, 2019

which meter use for remote disconnection

Forums
General discussion

Dear sir,
kindly tell me one meter name which is support for remote connect/disconnect

By chavar , 29 May, 2019

Meter uptime

Forums
General discussion

Hello.

Is there a DLMS code for reading the meter uptime? We use our meters in for street lighting power networks which turn on and off automatically.

Any help is appreciated.

Thank you

By Amiya , 21 May, 2019

Remote connect and disconnect

Forums
General discussion

Dear sir,
kindlly reply me OBIS code for remote connect and disconnect.

By qu3st1on , 17 May, 2019

EDMI ATLAS Mk10A communication problem

Forums
General discussion

Hey, all I'm new on smart meters and i really need some help with this one i cant seem to get any communication either with rf or rs485 to my serial terminal?

Does anyone have communication with the device ?

By FredC , 14 May, 2019

Looking for C++ Source

Forums
General discussion

Hi,

I am new to Security Suite Zero and I am using an open source algorithm for Encryption and Decryption successfully for AARQ and AARE (Send and Receive only). I am able to verify results with the DLMS translator provided by Gurux. Unfortunately the algorithm does not have an option to Generate the GMAC Password (16 byte Challenge input yields 17 byte password). It only has inputs for the same size input and output lengths.

By natali , 10 May, 2019

Need reference for HDLC data byte

Forums
General discussion

hi

i have a problem to understand concept of the byte that use in the below sample masagge
please help me to find reference manual for simple describe this SNRM & AARQ & AARE structure means

--> SNRM including proposed parameter (client_max_receive_pdu_size=240)
--> 0x7E, 0xA0, 0x0F, 0x21, 0x41, 0x93, 0x01, 0x37, 0x81, 0x80, 0x03, 0x06, 0x01,
0xF0, 0xEC, 0x15, 0x7E

By bleg , 15 April, 2019

Purpose of ‘Capture’ action in ProfileGenerics

Forums
General discussion

What exactly does Capture action do?
Every PG has its dedicated data buffer inside of a meter.
My meter writes events into logbooks as soon as they happen (attribute #7 of PG is updated automatically).
Why Do i need to execute the Capture Action?

By bleg , 9 April, 2019

Reading Compact Frames

Forums
General discussion

Hello Gurux experts.
Reading multiple Dlms objects in one request via CompactFrame (CF) is very convenient thing.
But how to properly read CF from Gurux Java?
I know the CF strucutre in terms of DLMS objects.
How do i parse the octet string that comes in?
Is there a standartized way in gurux library?
Thank you.

By bleg , 8 April, 2019

Profile Generic buffer is not read fully

Forums
General discussion

Hello Gurux experts!

I am reading SamGas RSE meter via OpticalPort using DLMSDirector.
The problem is: when i read ALL values, i still get just a part of it. (11 of 70 on screenshot)
I also tried reading by range or dates, but meter returns error in both cases.
What am i missing?

Pagination

  • Previous page
  • 52
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Possible memory leak in file dlms.c, getCompactArrayItem(), getCompactArrayItem2()
  • Official Gurux.DLMS.Client.Example.Net fails during High GMAC secure association (Invalid PDU), while Gurux Director connects successfully
  • gurux_dlms.GXDateTime.GXDateTime object Error in Python
  • T_APPL_DATA_LN_N1 subtest 3 fails on an LN-only server regardless of the response to a non-existing-object GET
  • Version mismatch between Gurux.DLMS 9.x and Gurux.Common/Gurux.Serial 8.x
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin