By EO , 25 March, 2020

Raspberry Pi Compatible Optical Probe

Forums
General discussion

Hi,

Can you kindly recommend an optical probe that is compatible with the GURUX DLMS for Raspberry Pi?

Do appreciate a link or name.

Thanks!

By ramdev3108 , 19 March, 2020

HLS Authentication problem

Forums
General discussion

Hi,
We are designing the DLSM server application ,When we are interfacing Highlevel-GMAC we are facing problem is that ,once authenticate frame was received, GURUX Tool Raising an error “Long set or Write Aborted” where is the problem is going we are not getting an idea.The resultant frames has given below.
would you please suggest the correct thing.

the server KEYS are

global key is 0123456789ABCDEF
authentication key is 0123456789ABCDEF
system title is ABC00001

By gkrishna , 14 March, 2020

Communicate with Non DLMS meters

Forums
General discussion

Hi All,

Is it possible to convert NON-DLMS Energy meters to DLMS meters by using external device.
If it is possible, How the communication will be and how can we get the data from non DLMS energy meters?
what is the medium of communication?

By ramdev3108 , 10 March, 2020

Attribute_Error_Response

Forums
General discussion

Dear Sir/Madam,
I have couple of doubts while developing the meter server application.
1).What is error response for the "not defined attribute", When i am trying to GET/SET/ACTION on it,
2).My server LLS password is 5 bytes if any one write more than 5 bytes LLS password ,what is the error response the meter has to give.

Regards
DLMS Team

By iMeter , 2 March, 2020

HDLC protocol

Forums
General discussion

Hi.
Some questions on HDLC:
1. Has anyone encountered such an algorithm?
The flag sequence must never occur within the content of a frame otherwise it could be confused with an intentionally sent flag. A technique known as 0-bit insertion is used to prevent random data synthesizing a flag. The technique is said to make HDLC transparent, since any stream of bits may be present between the open and closing flag of a frame. The transparency is achieved by encoding the data by inserting a 0-bit after any sequence of 5 consecutive 1's within the payload.

By Varun Sharma , 28 February, 2020

Write mdip value

Forums
General discussion

Hello Sir,
I need to know how can i write mdip value in meter using c# code.
For example:- GXDLMSData mdip = new GXDLMSData("1.0.0.8.0.255");
Now how can i write the value of attribute 2 in this.

I want to set the values for below obis
1.0.0.8.0.255 = Ch. 0 Measurement period 1, for averaging scheme 1
1.0.0.8.4.255 = Ch. 0 Recording interval 1, for load profile
1.0.0.8.5.255 = Ch. 0 Recording interval 2, for load profile

Thank you

By Mohanraj , 27 February, 2020

Reading profile generic in wrapper layer - failed

Forums
General discussion

Hi Mikko,

trying to read profile generic data using WRAPPER.But unable to process the response. "Device reports a hardware fault"
Below is the code snippet and log

By Mohanraj , 26 February, 2020

Reading profile generic data by readRowsByRange - failed

Forums
General discussion

Hi Mikko,

Hope you are doing good.
Below is the code snippet for reading profile generic data by Range(FromDate:25-02-2020 14:19:00 and ToData:26-02-2020 14:19:00).
GuruxGXDLMSDirector is working perfectly. but below code snippet is not working. getting an error message "ReadObject failed Access Error : Device reports a inconsistent Class or Object."
Frame type is also different when we compare with our code and director log.

By Varun Sharma , 20 February, 2020

Read and set Activity Calender

Forums
General discussion

Hello,

How can i read and set Activity calender using my c# project.Plz give a sample code.?
Thank You

By gkrishna , 18 February, 2020

Need Energy Meter which supports DLMS with Serial and TCP

Forums
General discussion

Hi All,

We have started planning implementing DLMS support in our IOT device. IN order to test or experiment, we need DLMS support energy meter device and also it should support both TCP and serial as well.

Please suggest me some good products which I can buy.

Thanks in advance.

Thanks,
Gopi Krishna M

Pagination

  • Previous page
  • 45
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 06/15/2026 - 08:52
    gurux.dlms.c 9.0.2606.1501
  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection