By Administrator , 9 May, 2025

Gurux.DLMS.Python 1.0.181

The following important issues are resolved in this version:

GXDLMSPushSetup portReference LogicalName renamed to logicalName.

By Administrator , 9 May, 2025

GXDLMSPushSetup portReference LogicalName renamed to logicalName.

Project
Gurux.DLMS.Python
Status
Closed (fixed)
Priority
Normal
Category
Bug report
By Rosa , 8 May, 2025

Contadores Landys bloqueados

Forums
Gurux DLMS for Android

Buenas tardes,

He experimentado con todos los contadores LGZ que he probado que, si pongo una dirección de cliente errónea, el contador se bloquea temporalmente (1-2 minutos) y no me permite reconectarme usando la dirección de cliente correcta en ese tiempo, sin embargo, si cambio cualquier otro parámetro, aunque de error para conectarse, luego me permite conectarme al instante. He probado con otros contadores como ZIV, Sagecom... y ninguno me ha dado ese problema, solo me ocurre con LGZ.

¿Porqué ocurre esto? ¿Habéis detectado este error?

By Incidencias , 8 May, 2025

DLMS Simulator .NET | Invalid Read values and errors when simulating

Forums
Gurux.DLMS

Greetings,

Im currently using DLMS Simulator to simulate a device, but im struggling to first read the device data correctly, I firstly used the integrated read function of the simulator, the conexion is correct and I generate a .xml but I get "invalid" values from the reads:

Command: "Gurux.DLMS.Simulator.Net.exe -h (ip) -p 4059 -i WRAPPER -c 2 -s 1 -a Low -P (password) -t Verbose -o fileoutput.xml"

By MikeAtson1 , 8 May, 2025

Failed at Conformance Test

Forums
DLMSDirector

Hi,

I already shared a message about that. Still not found solution. And also I tried Landis+Gyr E550 meter.

By Pablob , 8 May, 2025

Get block transfer error

Forums
Gurux DLMS for ANSI C

Hello!

I have implemented a DLMS server on a Texas Instruments C2000 microcontroller, based on the ANSI C server examples. Communication is established over PLC, and I have already implemented serialization of the PRIME API on the C2000. The DLMS server interface I am using is TYPE_PDU.

By Administrator , 7 May, 2025

UI added for Push setup, Profile generic, Local port setup, HDLC setup, IP4 Setup, TCP/UDP Setup and GPRS Setup.

Project
Gurux.DLMS.Android
Status
Closed (fixed)
Priority
Normal
Category
Feature request
By Administrator , 7 May, 2025

Gurux.DLMS.Android 2.0.14

The following important issues are resolved in this version:

UI added for Push setup, Profile generic, Local port setup, HDLC setup, IP4 Setup, TCP/UDP Setup and GPRS Setup.

By srikanthj , 7 May, 2025

using dlms python sdk i am facing invocation couter issue

Forums
Gurux.DLMS

srikanth@phytec:~/work/smart-energy-meter/smart-meter-integration/custom-dlms-meter-reader/dlms-python/yitran-dlms-python/Gurux.DLMS.Python/Gurux.DLMS.Client.Example.python$ python3 mqtt_obis.py
Starting MQTT client...
Connected to MQTT broker with result code 0
Subscribed to topics: meter/parameters, meter-id, obis-code
Received message from topic meter-id: EP1240009
Received meter-id: EP1240009
Meter ID set to: EP1240009

By Shekhar , 7 May, 2025

TOD GXDLMSDayProfile

Forums
DLMSDirector

Dear Sir,
This code for modified tod time error not coming but in meter not updated.
Encription & authentication key=bbbbbbbbbbbbbbbb
HLS=BBBB1234BBBB1234

Pagination

  • First page
  • Previous page
  • …
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • Page 61
  • Page 62
  • Page 63
  • …
  • Next page
  • Last page
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin