By muraligowda980… , 2 December, 2025

DLMS Stack hang during Firmware Upgrade

Forums
Gurux DLMS for ANSI C

Hi,

I am trying to update the meter firmware using GuruxDLMS.c library. I am able to establish connection with the meter in Firmware Upgrade mode. Post this, while i am trying to read Image transfer enable status, block size and image transferred block status, meter isn't responding for the one of the TX sent by stack and stack is hanging in com_read function while returning with DLMS_ERROR_CODE_RECEIVE_FAILED error.

Request you let me know what could be the reason.

Please find below details for your analysis.

By Administrator , 1 December, 2025

Gurux.DLMS.Python 1.0.193

The following important issues are resolved in this version:

fix: Notification issues fixed.

By Administrator , 1 December, 2025

fix: Notification issues fixed.

Project
Gurux.DLMS.Python
Status
Closed (fixed)
Priority
Normal
Category
Bug report
By jack 001 , 1 December, 2025

Itron SL7000 load profile return error

Forums
Gurux DLMS for ANSI C

Hi Mikko, i am back working on the itron meter data reading. I created new forum post because i can't reply on the old one. 
After trying out the update, the issue on reading Itron SL7000's load profile (0.0.99.1.0.255) still persists
- if i read capture objects first (index 3), it returns error 13 : DLMS_ERROR_CODE_ACCESS_VIOLATED
- if i read without it, it returns error 258 : DLMS_ERROR_CODE_INVALID_PARAMETER, but i can see some data in the traces, and i can use GXDLMSTranslator to translate and get the data

By Bhaumik , 27 November, 2025

Convert string to octate string

Forums
General discussion

Hi Mikko,

I have to write the following array in the meter.

<Array Qty="01">
<Array Qty="02">
<Structure Qty="02">
<OctetString Value="070000FF"/>
<OctetString Value="060000FF"/>
</Structure>
<Structure Qty="02">
<OctetString Value="080000FF"/>
<OctetString Value="090000FF"/>
</Structure>
</Array >
</Array>

By andre538 , 27 November, 2025

method call result

Forums
Gurux.DLMS

Hello Mikko,

What should I do to get method call result?
For example, object target is of GXDLMSImageTransfer type.

Let's use method 3 "image verify".
As written in BlueBook "The result of the invocation of this method may be success, temporary_failure or other_reason."

Following code works ok:
reader.readDataBlock( target.imageVerify(reader.client), reply)
How should I check that result is success, temporay failure or something else?

Is it reply.error values according to green book or something else?

By pratim1988 , 27 November, 2025

Regarding android app

Forums
Gurux.DLMS

Hello Sir,
I am using below dependency in my Android project. But when I ran my project with minSDK version 29 its gives error so, to using those I need to maintain my minSDK version 31. Is it possible to run in 29?
implementation(libs.gurux.dlms)
releaseImplementation(libs.guruxDlmsAndroid)
implementation(libs.gurux.serial.android)
implementation "org.gurux:gurux.common.android:3.0.4"
implementation "com.github.mik3y:usb-serial-for-android:3.9.0"

By thiesens , 26 November, 2025

Release download

Forums
DLMSDirector

Hi

Did you remove all releases of GXDLMSDirector?
I cant find any download

By JoshuaStar , 25 November, 2025

Getting data from dlms cat-c3 bi-directional meter

Forums
Gurux.DLMS

Hi everyone,

I’m trying to interface a Schneider Electric / L&T DLMS Category C3 bi-directional energy meter using its RS232 port, which is exposed using an RJ11 4-pin connector. I’m stuck at a few points and would really appreciate guidance.

1. RJ11 RS232 Pinout (4-pin) for L&T / Schneider meter

The meter manual is not clear on the RS232 pinout.
Does anyone know the exact mapping for:

Pin 1 – ?

Pin 2 – ?

Pin 3 – ? (ground?)

Pin 4 – ?

A confirmed TX, RX, GND assignment would help a lot.

2. No voltage on pins?

By andre538 , 25 November, 2025

GetRequestWithList Translator error

Forums
DLMSDirector

Hello Mikko,

there is a bug in Gurux DLMS Translator while processing GetRequestWithList

sample data exchange:

TX: 08:26:48 7E A0 39 02 23 61 76 ED 4D E6 E6 00 C0 03 C1 04 00 03 01 00 00 06 00 FF 02 00 00 03 01 00 00 06 01 FF 02 00 00 03 01 00 00 06 02 FF 02 00 00 03 01 00 00 06 03 FF 02 00 A7 4F 7E
RX: 08:26:48 7E A0 21 61 02 23 96 9B D4 E6 E7 00 C4 03 C1 04 00 12 08 FC 00 12 00 05 00 12 00 32 00 12 00 3C FD 80 7E

Pagination

  • First page
  • Previous page
  • …
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
  • Page 21
  • Page 22
  • …
  • Next page
  • Last page
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin