  2. Can't Recognize Packets When Exchanging Data With An Electric Meter Natris-I100

Can't recognize packets when exchanging data with an electric meter Natris-I100

By Chesterfield , 31 January, 2026
Forums
Gurux.DLMS

I am trying to analyse traffic between wireless module RF-433 and electric meter Natris-I100 but some parts of the messages remain unclear.

1. The RF-module sends SNRM frame:
7E A0 21 02 23 21 93 48 55 81 80 14 05 02 07 EE 06 02 07 EE 07 04 00 00 00 01 08 04 00 00 00 01 B5 D4 7E

2. Meter replies by UA frame:
7E A0 21 21 02 23 73 8F 72 81 80 14 05 02 02 00 06 02 02 00 07 04 00 00 00 01 08 04 00 00 00 01 6F EF 7E

3. The RF-module sends data, that I can't understand:
7E A0 1A 02 23 21 10 E6 70 E6 E6 00 FF 01 0A 20 08 CD 2C 39 86 00 21 10 02 3C FA 7E

namely, this part: FF 01 0A 20 08 CD 2C 39 86 00 21 10 02

I assume that the serial number of the counter 021221008639 is being sent.

4. Meter replies: 7E A0 0F 21 02 23 30 39 03 E6 E7 00 FF FD 0F AC 7E

5. RF-module sends data:

7E A0 45 02 23 21 32 68 6D E6 E6 00 FF 01 0A 21 33 00 01 00 10 00 01 00 2B 60 29 A1 09 06 07 60 85 74 05 08 01 01 A6 0A 04 08 00 00 00 00 00 00 98 00 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 40 1F 7F 00 C8 F8 B9 7E

It seems to be AARQ frame, but some parts of the message remain unclear:

a. FF 01 0A 21
b. 33 00 01 00 10 00 01 00 2B
c. A6 0A 04 08 00 00 00 00 00 00 98 00

6. Reply from meter: 7E A0 0F 21 02 23 52 2D 43 E6 E7 00 FF FD 0F AC 7E

What does the sequence FF FD mean?

Thank you for any help.

Profile picture for user Kurumi

Kurumi

3 months 3 weeks ago

Hi, The AARQ frame is not…

Hi,

The AARQ frame is not correct. This is explained in DLMS standards and it's too complicated to explain in the forum. It's easier if you get the DLMS standards.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin