By nissi , 8 January, 2026

old meter take to much time(l&t)

Forums
Gurux.DLMS

Hi,
i have l&t meter(ER300P) 2016 make it working in both optical and rs485 but it take to much time for InitializeConnection around 4 min for both GXDLMSDirector and gurux dlms client example

By Windmill , 7 January, 2026

Unable to connect L&T ER300P Meter

Forums
DLMSDirector

Dear sir,

I'm trying to connect L&T ER300P meter by Optical probe. It is not able to connect the meter. And it show a pop up message called - Failed to receive reply from the device in given time.

Here is the Error and Device Property Details
1. https://ibb.co/tTSRbvGw
2. https://ibb.co/W4vJJk4v

By Sief , 31 December, 2025

Online vs Offline DLMS translator

Forums
Gurux.DLMS

Hello All,

I was trying to parse an HDLC frame(not DLMS) using GXDLMS DLMS translator.
I found that the online version of the tool parses the frame in a different manner than the offline tool, specifically the HDLC payload.
The online version always deducts the first byte of the payload while the offline tool shows the whole payload as expected.
I'm using HDLC type format 3 which shows that the payload starts right after the 2-bytes Header Check Sum (HCS).

Is there a reason why the offline parsing mechanism differ than the online one ?

By FlyOcean , 31 December, 2025

Simulator meter connect need Help!

Forums
General discussion

Hello, everyone

I want to connect the simulator meter with the template (LN-v2-GMacWithAuthenticationEncyption.xml).

I started the simulator with command(.\bin\Release\net9.0\Gurux.DLMS.Simulator.Net -S COM3 -t Verbose -x .\Templates\LN-v2-GMacWithAuthenticationEncyption.xml)

After that, i started the command to connect( no issue with the physical layer), but it did not work, the aare is failed. is my command wrong? or other ? i need help. thank you for looking.

By Adetutu22 , 30 December, 2025

HAN Interface of meter

Forums
DLMSDirector

Hello,

I am working with a smart energy meter using Gurux.

I successfully connected to the meter using the optical interface (IEC 62056-21) and was able to:

Read meter data Zpa am165

Read the meter name/identification

I then tried to connect using the Ethernet (HAN) port with:

Laptop → USB-to-Ethernet adapter

Direct Ethernet cable to the meter

No router in between

The Ethernet link does not come up (Windows shows network cable unplugged,)

By Administrator , 29 December, 2025

Gurux.Serial.Android 3.0.5

The following important issues are resolved in this version:

Implemented RTS and CTS hardware flow control support for CH34x chipsets.

By Administrator , 29 December, 2025

Implemented RTS and CTS hardware flow control support for CH34x chipsets.

Project
Gurux.Serial.Android
Status
Closed (fixed)
Priority
Normal
Category
Support request
By nissi , 24 December, 2025

how to read multiple meters same serial connection

Forums
Gurux.DLMS

i am using C# Gurux DLMS.Client.Example and trying to write own based on that example now how can read multiple meters at a same time in single connection dose i know the we need Disconnect() for every new meters before go to next meter how to do that or this method is wrong!

By vladoam , 24 December, 2025

CH340 RTS/DTR

Forums
Gurux.Serial

Hi, I'm trying to read meter with usb2rs485 converter (https://github.com/WeActStudio/WeActStudio.USB2RS485V2/tree/master) it uses ch340 chipset (https://github.com/WeActStudio/WeActStudio.USB2RS485V2/blob/master/Doc/…). If I understand correctly my problem is that gurux serial android for ch340 does implement RTS/DTR? In windows everything works with gurux director and CH341SER driver.

By Bhaumik , 23 December, 2025

Time Conversion

Forums
Gurux.DLMS

HI Mikko,

I have received bytes from meter as 09 04 05 00 ff ff

Now while I am converting value it is coming as below:

-- 05:00:*.255

I want value like 05:00:*

Can you please provide sample code for that in c# so I can convert it.

Pagination

  • First page
  • Previous page
  • …
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • …
  • Next page
  • Last page
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin