By rishab_tp , 19 January, 2026

writing Error "Service not allowed"

Forums
Gurux.DLMS

We are writing Passive TOU day profile which have 4 day table and 8 rate in each table, when we write all 4 day table with 8 rate in all table and it start transfer success for 2-3 packet and post this next command failed and getting error "Service Not Allowed", but when we reduce the data means select only few rate in all table so getting all success.
We analyse that if Payload size is <512 Byte able to write successfully in block transfer, but if no. of payload >512 byte this scenario regenerated using library as well as DLMS director.

By zolboo1225@ , 19 January, 2026

High GMAC meters can’t authenticate – can’t read invocation counter

Forums
General discussion

Hi all,

We have ~500 ameter300 DLMS meters deployed across the country. They all use the same key material (system title 5753450000000001, client title 434C4E5400000001, auth key D0…DF, block key 00…0F, GMAC password 0x3333…). The legacy OPC client (C# / MyDaAddressSpaceDevice) talks to them just fine, but it hardcodes Ciphering.InvocationCounter = 1.

By andre538 , 19 January, 2026

GetRequestWithList Translator error

Forums
DLMSDirector

Hello Mikko,

any news about GetRequestWithList Translator error?

Unfortunately can't comment old post, so decided to create new one.

Br, Andrew

By supernan , 19 January, 2026

Connection is permanently rejected. No common AcseVersion

Forums
DLMSDirector

Hi,

I'm trying to connect to wasion meter. the security is using HighGMAC. and the response is "Connection is permanently rejected. No common AcseVersion"
I try many combination on client, logical, physical address and i think the current value is correct because the meter responding and responsive. What could possibly go wrong? Is it regarding the title, block cipher, etc?

By Administrator , 14 January, 2026

Gurux.DLMS.Python 1.0.196

The following important issues are resolved in this version:

Communication port protection implemented.

By Administrator , 14 January, 2026

Communication port protection implemented.

Project
Gurux.DLMS.Python
Status
Closed (fixed)
Priority
Normal
Category
Feature request
By Bhanu Prakash , 13 January, 2026

6-digit field values from meter not fully received (only 5 digits shown)

Forums
DLMSDirector

Hello Gurux Team,

We are currently facing an issue while reading meter data using Gurux DLMS libraries.

In the field, some meters are configured to return values with 6 digits (for example, energy or billing-related parameters). However, while reading these values through Gurux, we are consistently receiving only 5 digits, even though the meter display shows 6 digits.

Observations:

The meter display clearly shows a 6-digit value.

Gurux response contains only 5 digits for the same OBIS/field.

By Windmill , 13 January, 2026

Gurux DLMS Android App

Forums
Gurux DLMS for Android

Hi sir,

Where can i download Gurux android app.

By Bhanu Prakash , 12 January, 2026

AMR support for bidirectional meters.

Forums
DLMSDirector

I would like to know whether the Gurux DLMS supports AMR for bidirectional meters used in SRTPV applications. Any guidance would be appreciated.

By Vinas , 12 January, 2026

addition of new object in object list, meter not working

Forums
Gurux DLMS for ANSI C

hi, am new in DLMS community.

this is my object lis.

gxObject* ALL_OBJECTS[] = {
BASE(association),
BASE(ldn),
BASE(hdlc),
BASE(clock1),
BASE(activePowerL1), BASE(voltageR), BASE(currentR), BASE(frequency),
};

below is the association view for this list

Pagination

  • First page
  • Previous page
  • …
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • …
  • Next page
  • Last page
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin