By KostaG, 15 March, 2023

Capture objects in ansi c

Forums
General discussion

Hi,

How can I implement and replicate in ANSI C, in the client side of the program, the action of Capture Objects of profile generics.

This is the dialog GXDLMSDirector shows when I press the Capture action:

12:50:08 Method object 1.0.99.1.0.255, interface ProfileGeneric
TX: 7E A0 1B 03 23 76 89 D6 E6 E6 00 C3 01 C1 00 07 01 00 63 01 00 FF 02 01 0F 00 73 A3 7E
12:50:08
RX: 7E A0 11 23 03 96 21 CD E6 E7 00 C7 01 C1 00 00 FC B4 7E

I want to implement in C this action, in the client side, but I don´t know how to do it.

Thanks.

By zeus8497st, 24 February, 2023

Meaning of HLS secret

Forums
General discussion

Hi kurumi

By delanou, 23 January, 2023

Priority Gurux Objects DLMS/COSEM

Forums
General discussion

Hi, I was reading the DLMS green book, where it explains priority management and says the following:

"9.1.4.4.4 Priority handling
For data transfer services using LN referencing, two priority levels are available: normal (FALSE) and high (TRUE). This feature allows receiving a response to a new request before the response to a
previous request is completed.

By labasvakaras, 15 January, 2023

Gurux DLMS SHA256 does not work correctly with C client.

Forums
General discussion

used GXDLMSDirector and everything works fine. But when I try to use C example client with these arguments:
./gurux.dlms.client.bin -h localhost -p 4061 -c 22 -a HighSHA256 -P Gurux -T 4142434445464748
I get error:
Connecting to localhost:4061
InitializeConnection
Access Error : Device reports Read-Write denied.

Also tried to use .NET client and everything works fine.

By mansour, 7 January, 2023

Indian meters and 4G LTE connection

Forums
General discussion

Hi Mikko,

Happy new year !

I need your advice please, I have to make some tests on indian meters (Capital Power System and L&T), this 2 meters have 2 connection types (HDLC with optical probe and 4G modem).
I am facing a problem, I didn't manage to connect them here in France, I have tried several telecom operators but I see a GRPS connection failed error code on the meter and the APN doesn't give me an IP address (the 2 cosem objects ip4setup and ip6setup remain empty).

By kevin jose minj, 6 January, 2023

Timestamp

Forums
General discussion

When I am reading the billing profile date the timestamp is getting as hexadecimal is there any way to convert it into readable form?
This is the output I am getting

By labasvakaras, 5 January, 2023

bug in dlms C?

Forums
General discussion

Hello, tried your dlms.c library, wanted to ask if this is a bug or I am using library wrong?

String data is trash value although data in reply is good. Scrolled through your cosem metods and saw:
cosem_setGsmDiagnostic():

memcpy(object->operatorName, value->strVal, value->strVal->size);

should'nt it be

memcpy(object->operatorName, value->strVal->data, value->strVal->size);

?

made a patch myself and it works.

By kevin jose minj, 5 January, 2023

Profile Generic

Forums
General discussion

When I am reading the events it is not possible to read one by one objects it is throwing some invalid block number error.what is the issue?Here us the output

By ape, 4 January, 2023

Echelon 83332 & Gurux.DLMS.Push.Listener

Forums
General discussion

Hi!

I live in Finland and I have Echelon 83332 meter. Seems that I'm receiving push messages from the device's optical port (ttyUSB0).

However I have no idea how to parse those messages. I'm looking for a way to read real-time energy consumption.

Any help would be highly appreciated. Is decryption key required in Finland? Operator is Caruna.

By chinmayghosh, 4 January, 2023

ModBUS to DLMS

Forums
General discussion

We have a panel meter. It doesn't have optical port and doesn't support DLMS protocol. 

It only have Rs 485 with ModBUS. 

So we need one solutions that will connect RS485 at meter and fetch ModBUS data, convert it to DLMS data and output port will be optical port.

Pagination

  • Previous page
  • 4
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 12/29/2025 - 10:38
    Gurux.Serial.Android 3.0.5
  • Mon, 12/15/2025 - 08:11
    Gurux.DLMS.Net 4.0.87
  • Fri, 12/12/2025 - 08:38
    Gurux.DLMS.Python 1.0.195
  • Thu, 12/11/2025 - 13:22
    Gurux.DLMS.Python 1.0.194
  • Thu, 12/11/2025 - 11:01
    gurux.dlms.java 4.0.88

New forum topics

  • Gurux DLMS Android App
  • AMR support for bidirectional meters.
  • addition of new object in object list, meter not working
  • old meter take to much time(l&t)
  • Unable to connect L&T ER300P Meter
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin