  1. Home
  2. General Discussion
Description

General discussion about Gurux community, forum, bugtracker, GXDN, web site, and / or products.

Image
By shaaa , 29 April, 2024

Windows COM ports

Forums
General discussion

Hi,

I am having an issue. When I put the COM port in source setting the program still cant read the data instead of just show same as not changing the COM port.

By mbathe , 30 March, 2024

Auto detection of meter server address

Forums
General discussion

Hello, please, I have a meter at my disposal that I want to connect to via the serial port, but I don't know the server address. Is there a way for me to automatically detect the server address of the meter, or is there another way I can connect to the meter without the server address?

Thank you in advance for your response.

By Giulia2 , 11 March, 2024

Clock_format_optionA, B,C

Forums
General discussion

Hi all,
I have a question.
I am studying how to sync clock on a meter and I stumbled upon this definition:
"The Deviation and the Clock Status may be defined or may be left undefined:"
Case A:deviaition not specified, clock status not specified
CAse B: deviation not specified, clock status with DST set to 80 or 00
CAse C: deviation is set to deviation from local time to UTC, clock status with DST bit 00.
My question are:
1.When we want to sync meter date, meter has to support all 3 methods?

By Burger , 26 February, 2024

Reading OBIS Code 1.8.0 Register Name Difference

Forums
General discussion

I try to read register with address 1.8.0 because according my research on internet 1.1.1.8.0.255 refers to total active import energy.

But according to returned message from Gurux and 62056-61, 1.8.0 is said to be Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0.

Do these two description mean the same or if not what causes the difference?

By Mohanraj , 3 January, 2024

TCP Wrapper is not working DLMS client example -ANSI C

Forums
General discussion

DLMS connection is success in DLMS Gurux Explorer with US mode on TCP Wrapper and below is the TX and RX log.

Log from Gurux DLMS Explorer - Connection on US and TCP wrapper

TX: 00 01 00 10 00 01 00 1F 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 62 1E 5D FF FF
RX: 00 01 00 01 00 10 00 2B 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 00 10 02 58 00 07

By 94r4d0x , 23 November, 2023

Use of local area networks on twisted pair with carrier signalling

Forums
General discussion

hi
I need to connect my meter with IEC 62056-31 protocol

Part 31:
Use of local area networks on twisted pair with
carrier signalling

it possible ?

By joenear , 8 November, 2023

Easiest smart meter with ECDSA signatures?

Forums
General discussion

I'm running a research project where we want to collect some readings from a smart meter that produces a public-key signature. We don't need to actually use the meter in any real deployment - it's purely a proof-of-concept experiment for a research project in cryptography. All we need to do is hook it up in a lab, and grab some readings from it on a computer.

By Olverine , 26 October, 2023

Electricity meters from Kaifa do not seem to transmit valid frames

Forums
General discussion

Here is an example of hexadecimal data received from the HAN port of a Kaifa MA304H4PSE:

7e a0 9a 01 00 01 10 12 10 e6 e7 00 0f 40 00 00 00 09 0c 07 e7 0a 14 05 12 3a 0f ff ff c4 00 02 12 09 07 4b 46 4d 5f 30 30 31 09 10 37 33 34 30 31 35 37 30 33 30 39 30 34 30 34 35 09 07 4d 41 33 30 34 48 34 06 00 00 01 a9 06 00 00 00 00 06 00 00 00 00 06 00 00 00 04 06 00 00 00 61 06 00 00 01 ac 06 00 00 05 c4 06 00 00 08 fa 06 00 00 08 fe 06 00 00 09 0f 09 0c 07 e7 0a 14 05 12 3a 0f ff ff c4 00 06 00 07 4b b5 06 00 00 00 00 06 00 00 64 3c 06 00 02 6e f6 4b 0b 7e

By Lotusv , 20 October, 2023

Gurux.DLMS package for OpenWRT

Forums
General discussion

Is there a Gurux.DLMS package for OpenWRT in the .ipk installation package?
If not, how can I install the libraries on OpenWRT myself?

By picklemamba , 28 September, 2023

What kind of communication stanard is this

Forums
General discussion

I am new to to smart meters, I was recently checking out a smart meter system, the gateway is a esp8266 which communicates to the data collector over mqtt with some hex format. other meters connects to the gateway meter with some sort of rf mesh NAN with 32 bit meter address similar to ipv4. the data collector publish to the topic with the name of the grid id of the gateway meter.

Pagination

  • Previous page
  • 3
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses