Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. General Discussion
Description

General discussion about Gurux community, forum, bugtracker, GXDN, web site, and / or products.

Image
By scratch_nk , 19 May, 2024

Contributing to DLMS

Forums
General discussion

Many thanks for the amazing s/w -- on of the best and nicest written OSS i've seen.

(Apologies in advance if this has been asked earlier; didn't find it anywhere) Do you have any documents on how to contribute?

By shaaa , 29 April, 2024

Windows COM ports

Forums
General discussion

Hi,

I am having an issue. When I put the COM port in source setting the program still cant read the data instead of just show same as not changing the COM port.

By mbathe , 30 March, 2024

Auto detection of meter server address

Forums
General discussion

Hello, please, I have a meter at my disposal that I want to connect to via the serial port, but I don't know the server address. Is there a way for me to automatically detect the server address of the meter, or is there another way I can connect to the meter without the server address?

Thank you in advance for your response.

By Giulia2 , 11 March, 2024

Clock_format_optionA, B,C

Forums
General discussion

Hi all,
I have a question.
I am studying how to sync clock on a meter and I stumbled upon this definition:
"The Deviation and the Clock Status may be defined or may be left undefined:"
Case A:deviaition not specified, clock status not specified
CAse B: deviation not specified, clock status with DST set to 80 or 00
CAse C: deviation is set to deviation from local time to UTC, clock status with DST bit 00.
My question are:
1.When we want to sync meter date, meter has to support all 3 methods?

By Burger , 26 February, 2024

Reading OBIS Code 1.8.0 Register Name Difference

Forums
General discussion

I try to read register with address 1.8.0 because according my research on internet 1.1.1.8.0.255 refers to total active import energy.

But according to returned message from Gurux and 62056-61, 1.8.0 is said to be Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0.

Do these two description mean the same or if not what causes the difference?

By Mohanraj , 3 January, 2024

TCP Wrapper is not working DLMS client example -ANSI C

Forums
General discussion

DLMS connection is success in DLMS Gurux Explorer with US mode on TCP Wrapper and below is the TX and RX log.

Log from Gurux DLMS Explorer - Connection on US and TCP wrapper

TX: 00 01 00 10 00 01 00 1F 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 62 1E 5D FF FF
RX: 00 01 00 01 00 10 00 2B 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 00 10 02 58 00 07

By 94r4d0x , 23 November, 2023

Use of local area networks on twisted pair with carrier signalling

Forums
General discussion

hi
I need to connect my meter with IEC 62056-31 protocol

Part 31:
Use of local area networks on twisted pair with
carrier signalling

it possible ?

By joenear , 8 November, 2023

Easiest smart meter with ECDSA signatures?

Forums
General discussion

I'm running a research project where we want to collect some readings from a smart meter that produces a public-key signature. We don't need to actually use the meter in any real deployment - it's purely a proof-of-concept experiment for a research project in cryptography. All we need to do is hook it up in a lab, and grab some readings from it on a computer.

By Olverine , 26 October, 2023

Electricity meters from Kaifa do not seem to transmit valid frames

Forums
General discussion

Here is an example of hexadecimal data received from the HAN port of a Kaifa MA304H4PSE:

7e a0 9a 01 00 01 10 12 10 e6 e7 00 0f 40 00 00 00 09 0c 07 e7 0a 14 05 12 3a 0f ff ff c4 00 02 12 09 07 4b 46 4d 5f 30 30 31 09 10 37 33 34 30 31 35 37 30 33 30 39 30 34 30 34 35 09 07 4d 41 33 30 34 48 34 06 00 00 01 a9 06 00 00 00 00 06 00 00 00 00 06 00 00 00 04 06 00 00 00 61 06 00 00 01 ac 06 00 00 05 c4 06 00 00 08 fa 06 00 00 08 fe 06 00 00 09 0f 09 0c 07 e7 0a 14 05 12 3a 0f ff ff c4 00 06 00 07 4b b5 06 00 00 00 00 06 00 00 64 3c 06 00 02 6e f6 4b 0b 7e

By Lotusv , 20 October, 2023

Gurux.DLMS package for OpenWRT

Forums
General discussion

Is there a Gurux.DLMS package for OpenWRT in the .ipk installation package?
If not, how can I install the libraries on OpenWRT myself?

Pagination

  • Previous page
  • 3
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin