  2. Reading OBIS Code 1.8.0 Register Name Difference

Reading OBIS Code 1.8.0 Register Name Difference

By Burger, 26 February, 2024
Forums
General discussion

I try to read register with address 1.8.0 because according my research on internet 1.1.1.8.0.255 refers to total active import energy.

But according to returned message from Gurux and 62056-61, 1.8.0 is said to be Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0.

Do these two description mean the same or if not what causes the difference?

Image

Burger

1 year 10 months ago

1.8.0 Total active import…

1.8.0 Total active import energy

Image
Profile picture for user Kurumi

Kurumi

1 year 10 months ago

Hi, In DLMS standard 1.1.1.8…

Hi,

In DLMS standard 1.1.1.8.0.255 means Sum Li Active power+ (QI+QIV) Time integral 1 Rate 0. You need to ask the meter vendor what is counted for total active import energy in this meter.

I believe that the meter manufacturer is using a shorter description and they mean the same, but you need to verify this from the meter vendor.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 01/14/2026 - 14:29
    Gurux.DLMS.Python 1.0.196
  • Mon, 12/29/2025 - 10:38
    Gurux.Serial.Android 3.0.5
  • Mon, 12/15/2025 - 08:11
    Gurux.DLMS.Net 4.0.87
  • Fri, 12/12/2025 - 08:38
    Gurux.DLMS.Python 1.0.195
  • Thu, 12/11/2025 - 13:22
    Gurux.DLMS.Python 1.0.194

New forum topics

  • 6-digit field values from meter not fully received (only 5 digits shown)
  • Gurux DLMS Android App
  • AMR support for bidirectional meters.
  • addition of new object in object list, meter not working
  • old meter take to much time(l&t)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin