Data objects missing

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

Profile picture for user oulahsensaid
By oulahsensaid , 24 February, 2023
Forums
DLMSDirector

GXDLMSDirector 9.0.2302.2001
Log created 22:34:42
Disconnect request
Disconnect request
7E A0 08 02 23 21 53 B1 A2 7E
Data send failed. Try to resend 1/3
Data send failed. Try to resend 2/3
Failed to receive reply from the device in given time.
Initializing serial connection.
IEC Sending:/?!<CR><LF>
HDLC received: /ACE5\2ACE6K_MK2_R2<CR><LF>
BaudRate is : 9600
Moving to mode E.
06 32 35 32 0D 0A
Send SNRM request.
7E A0 08 02 23 21 93 BD 64 7E

7E A0 23 21 00 02 00 23 73 F6 C5 81 80 14 05 02 00 80 06 02 00 80 07 04 00 00 00 01 08 04 00 00 00 01 CE 6A 7E
Parsing UA reply succeeded.
Send AARQ request.
7E A0 2C 02 23 21 10 AF 9F E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 62 1E 5D FF FF 88 55 7E

7E A0 3A 21 00 02 00 23 30 99 41 E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 10 1D 21 34 00 07 89 9B 7E
Parsing AARE reply succeeded.
Read object type Data index: 2
7E A0 1A 02 23 21 32 F6 72 E6 E6 00 C0 01 C1 00 01 00 00 2A 00 00 FF 02 00 12 80 7E

7E A0 25 21 00 02 00 23 52 B0 AD E6 E7 00 C4 01 C1 00 0A 10 41 43 45 36 36 31 4D 41 38 34 34 35 37 36 38 34 EE E1 7E

Image
Profile picture for user Kurumi

Kurumi

3 years 3 months ago

Hi, The available data…

Hi,

The available data objects might depend on the authentication level used. You need to change the authentication level to Low or High and change the client address.

After that, you can access more objects.

BR,
Mikko

Profile picture for user oulahsensaid

oulahsensaid

3 years 3 months ago

Problem solved, thank you…

Problem solved, thank you very much.
One more question please. Is OBIS code are the same for all meters? and which code for consumption quantity?

Profile picture for user Kurumi

Kurumi

3 years 3 months ago

In reply to Problem solved, thank you… by oulahsensaid

Hi, The basic idea is that…

Hi,

The basic idea is that the OBIS codes should be the same for all the meters. In reality, some meter manufacturers are using different OBIS codes. You can check available objects and their OBIS codes by reading the association view.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin