By Ondrej_Pokorny , 10 August, 2022
Forums
DLMSDirector

Hello Mikko,
when disconnecting Management Client wich has been succesfully connected using preestablished association, Director disconnects the client but sends no data to server.
Therefore server connection state keeps in PRE_ESTABLISHED (should be DISCONNECTED) which prevents connection of any other client.
I would expect client to send HDLC_CONTROL_COMMAND_DISC (0x02).

Thank You.

Best Regards
Ondrej

Profile picture for user Kurumi

Kurumi

4 years 1 month ago

Hi Ondrej,

Hi Ondrej,

The new version where this is improved is released in the next week.

BR,
Mikko

Ondrej_Pokorny

4 years 1 month ago

Hello Mikko,

Hello Mikko,
I confirm that version 9.0.2208.1502 disconnects preestablished connection correctly.
Thank You very much!

Best Regards
Ondrej

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • Anaglyfos Trading CC
  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin