By PaulAdebo , 5 May, 2020 Forums DLMSDirector Hello, For the COSEM Application tests in the GXDLMSDirector, can we know what these tests cases are? However, testing my meters the COSEM Application tests failed, and I really can tell why? See log below 10:55:33 AM COSEM Application test #1. SNRM 7E A0 07 03 21 93 0F 01 7E 10:55:33 AM 7E A0 20 21 03 73 73 98 81 80 14 05 02 00 46 06 02 00 46 07 04 00 00 00 01 08 04 00 00 00 01 7D D6 7E 10:55:33 AM Reading object 0.0.40.0.0.255, interface AssociationLogicalName 7E A0 19 03 21 10 7F DA E6 E6 00 C0 01 C1 00 0F 00 00 28 00 00 FF 01 00 F9 79 7E 10:55:33 AM COSEM Application test #1. Read logical name 7E A0 19 03 21 10 7F DA E6 E6 00 C0 01 C1 00 0F 00 00 28 00 00 FF 01 00 F9 79 7E 10:55:38 Data send failed. Try to resend 1/3 10:55:43 Data send failed. Try to resend 2/3 10:55:48 AM Failed to receive reply from the device in given time. 10:55:48 Disconnect request 10:55:48 AM COSEM Application test #1. Disconnect request 7E A0 07 03 21 53 03 C7 7E 10:55:48 AM 7E A0 07 21 03 73 01 40 7E 10:55:49 AM COSEM Application test #1. SNRM 7E A0 07 03 21 93 0F 01 7E 10:55:50 AM 7E A0 20 21 03 73 73 98 81 80 14 05 02 00 46 06 02 00 46 07 04 00 00 00 01 08 04 00 00 00 01 7D D6 7E 10:55:50 AM COSEM Application test #1. AARQ 7E A0 2B 03 21 10 FB AF E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 00 1E 1D FF FF C5 E4 7E 10:55:50 AM 7E A0 37 21 03 30 6C 7C E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 10 19 00 51 00 07 81 19 7E UA and AARE frames are all accepted, so why is the verdict failed? I also observed, there was a read request after an SNRM frame, which was discarded by my implementation. Why is this so? Thanks Paul. Hi Paul, Hi Paul, This read request checks that meter is not returning anything if the connection is not established. (AARQ is not send). We'll add some more info so we know what phase fails. We'll release a new version on Friday. https://www.gurux.fi/gurux.dlms.ctt.tests1 BR, Mikko Hi, Hi, The New version is released and it writes more info to the log file. BR; Mikko Dear all, Dear all, Please help me in downloading DLMS data through the GuruX tool. Which version i have to use ?? Please share me the link for Gurux tool. Dear Vikas, Dear Vikas, Please, create a new topic if you have a new question. Download GXDLMSDirector and start with that. BR, Mikko
Hi Paul, Hi Paul, This read request checks that meter is not returning anything if the connection is not established. (AARQ is not send). We'll add some more info so we know what phase fails. We'll release a new version on Friday. https://www.gurux.fi/gurux.dlms.ctt.tests1 BR, Mikko
Dear all, Dear all, Please help me in downloading DLMS data through the GuruX tool. Which version i have to use ?? Please share me the link for Gurux tool.
Dear Vikas, Dear Vikas, Please, create a new topic if you have a new question. Download GXDLMSDirector and start with that. BR, Mikko
Hi Paul,
Hi Paul,
This read request checks that meter is not returning anything if the connection is not established. (AARQ is not send).
We'll add some more info so we know what phase fails. We'll release a new version on Friday.
https://www.gurux.fi/gurux.dlms.ctt.tests1
BR,
Mikko
Hi,
Hi,
The New version is released and it writes more info to the log file.
BR;
Mikko
Dear all,
Dear all,
Please help me in downloading DLMS data through the GuruX tool. Which version i have to use ??
Please share me the link for Gurux tool.
Dear Vikas,
Dear Vikas,
Please, create a new topic if you have a new question.
Download GXDLMSDirector and start with that.
BR,
Mikko