By PaulAdebo , 5 May, 2020
Forums
DLMSDirector

Hello,

For the COSEM Application tests in the GXDLMSDirector, can we know what these tests cases are?

However, testing my meters the COSEM Application tests failed, and I really can tell why? See log below

10:55:33 AM COSEM Application test #1. SNRM
7E A0 07 03 21 93 0F 01 7E
10:55:33 AM
7E A0 20 21 03 73 73 98 81 80 14 05 02 00 46 06 02 00 46 07 04 00 00 00 01 08 04 00 00 00 01 7D D6 7E
10:55:33 AM Reading object 0.0.40.0.0.255, interface AssociationLogicalName
7E A0 19 03 21 10 7F DA E6 E6 00 C0 01 C1 00 0F 00 00 28 00 00 FF 01 00 F9 79 7E
10:55:33 AM COSEM Application test #1. Read logical name
7E A0 19 03 21 10 7F DA E6 E6 00 C0 01 C1 00 0F 00 00 28 00 00 FF 01 00 F9 79 7E
10:55:38 Data send failed. Try to resend 1/3
10:55:43 Data send failed. Try to resend 2/3
10:55:48 AM Failed to receive reply from the device in given time.
10:55:48 Disconnect request
10:55:48 AM COSEM Application test #1. Disconnect request
7E A0 07 03 21 53 03 C7 7E
10:55:48 AM
7E A0 07 21 03 73 01 40 7E
10:55:49 AM COSEM Application test #1. SNRM
7E A0 07 03 21 93 0F 01 7E
10:55:50 AM
7E A0 20 21 03 73 73 98 81 80 14 05 02 00 46 06 02 00 46 07 04 00 00 00 01 08 04 00 00 00 01 7D D6 7E
10:55:50 AM COSEM Application test #1. AARQ
7E A0 2B 03 21 10 FB AF E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 00 1E 1D FF FF C5 E4 7E
10:55:50 AM
7E A0 37 21 03 30 6C 7C E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 10 19 00 51 00 07 81 19 7E

UA and AARE frames are all accepted, so why is the verdict failed?

I also observed, there was a read request after an SNRM frame, which was discarded by my implementation. Why is this so?

Thanks
Paul.

Profile picture for user Kurumi

Kurumi

6 years 1 month ago

Hi Paul,

Hi Paul,

This read request checks that meter is not returning anything if the connection is not established. (AARQ is not send).

We'll add some more info so we know what phase fails. We'll release a new version on Friday.

https://www.gurux.fi/gurux.dlms.ctt.tests1

BR,
Mikko

Profile picture for user Kurumi

Kurumi

6 years ago

Hi,

Hi,

The New version is released and it writes more info to the log file.

BR;

Mikko

Vikas Balichakra

6 years ago

Dear all,

Dear all,
Please help me in downloading DLMS data through the GuruX tool. Which version i have to use ??
Please share me the link for Gurux tool.

Profile picture for user Kurumi

Kurumi

6 years ago

Dear Vikas,

Dear Vikas,

Please, create a new topic if you have a new question.
Download GXDLMSDirector and start with that.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin