Association Logical Name

This object describes the connection between a client and a meter when objects are addressed by logical name. It defines which objects and operations the client can use, together with authentication and session settings.

When to use it

Use it when discovering the objects available to a meter reading client or checking why that client cannot write an attribute.

Attributes

1. Logical name

The OBIS code that identifies this object instance in the meter. Use it to distinguish this instance from other objects of the same class.

2. Object list (versions 0-2)

Lists the objects visible through this association, including their class, version, logical name and attribute and method access rights.

2. Object list (version 3)

Lists the objects visible through this association, including their class, version, logical name and access rights. Access rights specify permitted operations and their authentication, encryption and digital signature requirements.

3. Associated partners ID

Identifies the client and server application partners for this association.

4. Application context name

Identifies the application context, including logical name referencing and whether protected communication is used.

5. xDLMS context information

Describes supported services, message size limits and protocol settings used when establishing the session.

The supported services are described by the conformance settings.

6. Authentication mechanism name

Identifies the authentication method required to establish this association.

7. Secret

Holds the password or shared secret used by the selected authentication method. Some methods manage their keys through Security setup instead.

8. Association status

Shows whether the association is disconnected, being established or established.

9. Security setup reference

Identifies the Security setup object that manages protection for this association.

See Security setup for the protection settings referenced by this association.

10. User list

Lists the user identifiers and names allowed to use the association. An empty list allows any user identifier.

11. Current user

Identifies the user of the current association.

Versions

Attribute availability depends on the object version reported by the meter (version 0: attributes 1-8; version 1: attributes 1-9; version 2: attributes 1-11; version 3: attributes 1-11). Use the version-specific descriptions above when an attribute's meaning or representation differs.

Actions

1. Reply to HLS authentication

This action is used when HLS connection is used to send CtoS challenge.

2. Change HLS secret

This action is used to change HLS password.

3. Add object

Add new object to object list..

4. Remove object

Remove object from the object list..

3. Add user

Add new user to user list..

4. Remove user

Remove user from the user list..


  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv6 setup
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Utility tables
  • इमेज ट्रांसफ़र
  • Manufacturer custom objects
  • Account
  • Arbitrator
  • Array manager
  • Charge
  • CoAP diagnostics
  • CoAP setup
  • Communication port protection
  • Credit
  • Data protection
  • Function control
  • G3-PLC 6LoWPAN setup
  • G3-PLC MAC layer counters
  • G3-PLC MAC setup
  • LLC SSCS setup
  • LTE monitoring
  • M-Bus diagnostics
  • M-Bus port setup
  • Network time setup
  • Parameter monitor
  • PRIME application identification
  • PRIME MAC counters
  • PRIME MAC functional parameters
  • PRIME MAC setup
  • PRIME network administration data
  • PRIME physical layer counters
  • S-FSK active initiator
  • S-FSK MAC counters
  • S-FSK physical and MAC setup
  • S-FSK reporting system list
  • S-FSK synchronisation timeouts
  • Schedule
  • Short name association
  • STS payment token settings
  • Tariff plan
  • Token gateway
  • Twisted pair setup
  • Wireless mode Q channel
  • IPv4 setup
  • Register activation

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Layanan KCU THAMRIN No Cs.0817 819 444
  • KCU THAMRIN No Cs.0817 819 444
  • Finance WTC Mangga Dua Telpon:08218168291
  • Bandar Udara Internasional Halim Perdanakusuma
  • Bandar Udara Internasional Sultan Iskandar Muda
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin