Clock

A clock exposes the device date and time together with time-zone, daylight-saving and clock-quality settings. Other objects use this time for schedules and recorded timestamps.

When to use it

Use it to check a meter clock, correct its time or configure seasonal clock changes.

Attributes

1. Logical name

Identifies this object instance using its six-part OBIS code. Use it to distinguish this object from other instances of the same class.

2. Time

Shows the current device date and time, including the associated deviation and status fields.

3. Time zone

Sets the minutes added to local normal time to obtain UTC, excluding daylight saving. For a normal time zone of UTC+2, the value is -120.

See Deviation in date time below for the relationship between the time zone and daylight-saving adjustment, including the existing device-specific convention notes.

4. Status

Reports clock-quality flags, such as invalid or doubtful time and active daylight saving.

5. Begin

Defines when the daylight-saving period begins.

6. End

Defines when the daylight-saving period ends.

7. Deviation

Defines the daylight-saving adjustment in minutes.

This daylight-saving adjustment is distinct from the normal-time-zone deviation in attribute 3.

8. Enabled

Enables or disables the daylight-saving calculation.

9. Clock base

Identifies the source on which the device clock is based.

Actions

1. Adjust to quarter

Sets the meter’s time to the nearest (+/-) quarter of an hour value.

2. Adjust to measuring period

Sets the meter’s time to the nearest (+/-) starting point of a measuring period.

3. Adjust to minute

Sets the meter’s time to the nearest minute.

4. Adjust to preset time

Adjust to preset time

5. Preset adjusting time.

Preset adjusting time.

6. Shift time

Shifts the time by given minutes.

Deviation in date time

Deviation is saved to date-time value to tell deviation between the UTC and the meter. Deviation is count from time zone and daylight savings deviation. Daylight savings deviation is added only if daylight savings is enabled.

Deviation is causing problems because DLMS standard says the deviation is from normal time to UTC, not UTC time. Read more from Blue Book 4.1.6.1 Date and time formats.

if your meter is using from UTC to Normal time, set GXDLMSClient.UtcTimeZone to true or define DLMS_USE_UTC_TIME_ZONE in ANSI C. Example IDIS is using DLMS way and India, Saudi Arabia and Italy DLMS sub standards are using UTC to Normal time.

Below is example what this means using Paris Time zone (UTC+60).

  • DLMS and IDIS: -60 minutes.
  • India, Saudi Arabia and Italy: 60 minutes.
  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv6 setup
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Utility tables
  • इमेज ट्रांसफ़र
  • Manufacturer custom objects
  • Account
  • Arbitrator
  • Array manager
  • Charge
  • CoAP diagnostics
  • CoAP setup
  • Communication port protection
  • Credit
  • Data protection
  • Function control
  • G3-PLC 6LoWPAN setup
  • G3-PLC MAC layer counters
  • G3-PLC MAC setup
  • LLC SSCS setup
  • LTE monitoring
  • M-Bus diagnostics
  • M-Bus port setup
  • Network time setup
  • Parameter monitor
  • PRIME application identification
  • PRIME MAC counters
  • PRIME MAC functional parameters
  • PRIME MAC setup
  • PRIME network administration data
  • PRIME physical layer counters
  • S-FSK active initiator
  • S-FSK MAC counters
  • S-FSK physical and MAC setup
  • S-FSK reporting system list
  • S-FSK synchronisation timeouts
  • Schedule
  • Short name association
  • STS payment token settings
  • Tariff plan
  • Token gateway
  • Twisted pair setup
  • Wireless mode Q channel
  • IPv4 setup
  • Register activation

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Money Changer Indorate Prima Javalas Itc Kuningan Telp/Wa 081930338564
  • Money Changer Valuta Artha Mas Telp/Wa 081930338564
  • Layanan KCU THAMRIN No Cs.0817 819 444
  • Arthamas Citra Mandiri Money Changer Telp/Wa 081930338564
  • KCU THAMRIN No Cs.0817 819 444
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin