By Gurux Documentation , 10 November, 2026

Network time setup

This object configures time synchronization with an NTP server. It defines the server endpoint and any authentication needed to trust its time responses.

When to use it

Use it to keep a network-connected meter's clock synchronized with a central time service.

Attributes

1. Logical name

The OBIS code that identifies this object instance in the meter. Use it to distinguish this instance from other objects of the same class.

2. Activated

Enables or disables NTP time synchronization.

3. Server address

Identifies the time server by a resolvable host name or a textual IPv4 or IPv6 address.

4. Port

Sets the server's UDP port. The usual NTP port is 123.

5. Authentication

Selects no authentication, shared secret authentication or the supported autokey mechanism.

6. Keys

Lists shared authentication keys and their identifiers for shared secret operation.

7. Client key

Holds the server public key used by the supported IFF autokey authentication scheme.

  • Log in or register to post comments
  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv6 setup
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Utility tables
  • इमेज ट्रांसफ़र
  • Manufacturer custom objects
  • Account
  • Arbitrator
  • Array manager
  • Charge
  • CoAP diagnostics
  • CoAP setup
  • Communication port protection
  • Credit
  • Data protection
  • Function control
  • G3-PLC 6LoWPAN setup
  • G3-PLC MAC layer counters
  • G3-PLC MAC setup
  • LLC SSCS setup
  • LTE monitoring
  • M-Bus diagnostics
  • M-Bus port setup
  • Network time setup
  • Parameter monitor
  • PRIME application identification
  • PRIME MAC counters
  • PRIME MAC functional parameters
  • PRIME MAC setup
  • PRIME network administration data
  • PRIME physical layer counters
  • S-FSK active initiator
  • S-FSK MAC counters
  • S-FSK physical and MAC setup
  • S-FSK reporting system list
  • S-FSK synchronisation timeouts
  • Schedule
  • Short name association
  • STS payment token settings
  • Tariff plan
  • Token gateway
  • Twisted pair setup
  • Wireless mode Q channel
  • IPv4 setup
  • Register activation

Hire Us!

Latest Releases

  • Thu, 11/19/2026 - 10:57
    Gurux.DLMS.Python 1.0.204
  • Thu, 11/19/2026 - 10:12
    gurux.dlms.c 9.0.2611.1901
  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101

New forum topics

  • Layanan KCU THAMRIN No Cs.0817 819 444
  • KCU THAMRIN No Cs.0817 819 444
  • Finance WTC Mangga Dua Telpon:08218168291
  • Bandar Udara Internasional Halim Perdanakusuma
  • Bandar Udara Internasional Sultan Iskandar Muda
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin