S-FSK physical and MAC setup
Configures the radio frequency signalling used over the power line and the device's link layer addressing and repeater behaviour.
When to use it
For example, check signalling frequencies and the initiator address when a meter cannot synchronise with its concentrator.
Attributes
1. Logical name
Identifies this object instance by its six-part OBIS code. Use it to distinguish this object from other objects of the same class.
2. InitiatorElectricalPhase
Identifies the mains electrical phase used by the initiator.
3. DeltaElectricalPhase
Shows the electrical phase difference between this device and its initiator.
4. MaxReceivingGain
Limits the amplification used when receiving power line signals.
5. MaxTransmittingGain
Limits the signal gain used when transmitting onto the power line.
6. SearchInitiatorThreshold
Sets the received signal level that allows a sufficiently strong initiator to be selected promptly.
7. Frequency
Sets the two signalling frequencies used for mark and space symbols.
8. MacAddress
Contains the individual MAC address used to select this device.
9. MacGroupAddresses
Lists group MAC addresses for which this device accepts traffic.
10. Repeater
Controls whether the device may act as a repeater, including automatic repeater selection where supported.
11. RepeaterStatus
Reports whether the device is currently acting as a repeater.
12. MinDeltaCredit
Records the smallest difference between initial and remaining forwarding credit seen in valid addressed frames. It helps indicate the repetition distance from the sender.
13. InitiatorMacAddress
Contains the MAC address of the initiator used for synchronisation.
14. SynchronizationLocked
Reports whether the device is locked to its initiator for synchronisation.
15. TransmissionSpeed
Selects the bit rate used for S-FSK transmissions.