Communication port protection
This object protects a communication port by blocking access after repeated failed attempts. It also records failures and shows whether the port is currently locked.
When to use it
Use it to limit repeated unsuccessful access attempts on a meter's remote communication port.
Attributes
1. Logical name
The OBIS code that identifies this object instance in the meter. Use it to distinguish this instance from other objects of the same class.
2. Protection mode
Selects permanent locking, locking after failed attempts or unrestricted access through the port.
3. Allowed failed attempts
Sets how many failed communication attempts are allowed before temporary locking starts.
4. Initial lockout time
Sets the initial temporary lock duration in seconds once the failure limit is reached.
5. Steepness factor
Controls how quickly lock durations grow as further failed attempts occur.
6. Maximum lockout time
Limits the duration of a temporary lock, in seconds.
7. Port
Identifies the object representing the protected port. The reference can be empty when a separate port identification is not needed.
8. Protection status
Shows whether the port is unlocked, temporarily locked or permanently locked.
9. Failed attempts
Counts failed communication attempts since the last reset, regardless of the protection mode.
10. Cumulative failed attempts
Keeps the total failure count independently of the resettable failed attempts counter.