By cappa , 16 February, 2012

Has anyone sucessfully connected to any Kamstrup meters. Got a 382 K at the moment. It should respond to port 1025 But doesnt give any ok connection. Sometimes lucky on getting the setup from telnet to port 50100.

If successfully connected, how is the kamstrup model setup. Need details. I do think there might be a problem in the setup there and not the gurux software. Since the Kamstrup company keeps all information rather closed its hard to guess what to do. Any portscan on the meter is also unsuccessfull so guessing is the only option ( kinda many ports to guess from ). The default port as described in the standard setup doesnt respond to telnet either. One of the big issues with this meter is also guessing when it will respond, since also telnet to standard setup port doesnt response regulary.

The setup we got is a wifi connection. New meter with working cable (TCP/IP) is ordered but no need to say that the waiting time is long. Any suggestions and ideas would be welcome

kai

Profile picture for user Kurumi

Kurumi

14 years 8 months ago

Kamstrup meter

Hi,

Yes we are reading Kamstrup meters. Have you try with IF eye or just TCP/IP?
If you have eye try with GXDLMSDirector using following settings:
http://www.gurux.fi/GXDLMSDirectorExample

If you succeeded to read meter using eye you can see TCP/IP settings as well so
you do not need to search the TCP/IP port.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • Association refresh related issue
  • Need RJ45 pin configuration for Saral 300 and Saral 305 Secure meters
  • Query Regarding Class 63 Status Mapping Support in Gurux DLMS Python
  • Inhemeter
  • DLMS Server - Profile Generic - can't add too many items to profile generic capture object - how to set maximum profile entries
More

Who's new

  • Anand Raj
  • amir.jradi
  • JOEBID€N123
  • yogibear
  • Eric@li
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin