By shagufta , 14 May, 2024
Forums
DLMSDirector

HELLO SIR!! can you please provide me a solution my all conformance test is getting failed I tried more then 3 meters i'am getting same result please have a look at logs and provide me a solution to pass ma conformance test for meter

/*****LOGS*****/
11.49.11 Send SNRM request.
TX: 7E A0 07 03 21 93 0F 01 7E
11.49.11
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
11.49.11 Send AARQ request.
TX: 7E A0 2B 03 21 10 FB AF E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 62 1E 5D FF FF 88 55 7E
11.49.11
RX: 7E A0 37 21 03 30 6C 7C E6 E7 00 61 29 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 00 A3 05 A1 03 02 01 00 BE 10 04 0E 08 00 06 5F 1F 04 00 00 00 10 02 00 00 07 1C EA 7E
11.49.11 HDLC test #1. Disconnect request
TX: 7E A0 07 03 21 53 03 C7 7E
11.49.11
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
11.49.11 HDLC test #1. SNRM request
TX: 7E A0 07 03 21 93 0F 01 7E
11.49.11
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
11.49.11
SNRM request succeeded. MaxInfoLengthTransmit: 128 MaxInfoLengthReceive: 128 WindowSizeTransmit: 1 WindowSizeReceive: 1
11.49.11 HDLC test #1. Receiver Ready
TX: 7E A0 07 03 21 11 15 A6 7E
11.49.16 Data send failed. Try to resend 1/3 7E A0 07 21 03 11 15 00 7E
11.49.21 Data send failed. Try to resend 2/3 7E A0 07 21 03 11 15 00 7E 7E A0 07 21 03 11 15 00 7E
11.49.26 Data send failed. Try to resend 3/3 7E A0 07 21 03 11 15 00 7E 7E A0 07 21 03 11 15 00 7E 7E A0 07 21 03 11 15 00 7E
11.49.31 Failed to receive reply from the device in given time. 7E A0 07 21 03 11 15 00 7E 7E A0 07 21 03 11 15 00 7E 7E A0 07 21 03 11 15 00 7E 7E A0 07 21 03 11 15 00 7E
11.49.31
RX: 7E A0 07 21 03 11 15 00 7E 7E A0 07 21 03 11 15 00 7E 7E A0 07 21 03 11 15 00 7E 7E A0 07 21 03 11 15 00 7E
11.49.31
Receiver Ready failed.
11.49.31 HDLC test #1. Disconnect request
TX: 7E A0 07 03 21 53 03 C7 7E
11.49.31
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
11.49.31
<a href="https://www.gurux.fi/gurux.dlms.ctt.tests#hdlc1">Test #1 failed.</a>
11.49.31 HDLC test #2. SNRM request
TX: 7E A0 07 03 21 93 0F 01 7E
11.49.31
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
11.49.31
SNRM request succeeded. MaxInfoLengthTransmit: 128 MaxInfoLengthReceive: 128 WindowSizeTransmit: 1 WindowSizeReceive: 1
11.49.31 HDLC test #2. Illegal frame.
TX: 7E A0 07 03 21 53 03 C7
11.49.36
Data send failed. Try to resend 1/3
11.49.41
Data send failed. Try to resend 2/3
11.49.46
Failed to receive reply from the device in given time.
11.49.46
Index was out of range. Must be non-negative and less than the size of the collection.
Parameter name: index
11.49.46 Disconnect request
TX: 7E A0 07 03 21 53 03 C7 7E
11.49.46
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

Profile picture for user Kurumi

Kurumi

2 years 1 month ago

Hi, Your meter is not reply…

Hi,

Your meter is not reply for Receiver Ready message.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200
  • Mon, 06/15/2026 - 08:52
    gurux.dlms.c 9.0.2606.1501

New forum topics

  • Service not known error on gprs communication
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin