OBIS code for Average RMS voltage (percentage value)

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By Balveer Singh , 8 July, 2021
Forums
General discussion

Hi,
Greetings of the day,
I have to add a new parameter, Average RMS percentage voltage, in the instantaneous profile of the energy meter(3 Phase).
Can you suggest to me the OBIS code, although I have concluded from Blue Book, that it can be 12.7.0, but I think it should be applied if the unit is Volts, but I'm calculating this value in percentage,
So, kindly suggest, what OBIS code should be used?

Profile picture for user Kurumi

Kurumi

4 years 11 months ago

Hi,

Hi,

You can use GXDLMSTranslator to find correct OBIS code.
https://www.gurux.fi/GuruxDLMSTranslator

Remove OBIS code and apply the description to filter.
OBIS code might also be defined in country-specific versions.

BR,
Mikko

Balveer Singh

4 years 11 months ago

Thank You, Sir ! Although it

Thank You, Sir ! Although it is very helpful, But I didn't find the OBIS code for the respective parameter, even I didn't found any parameters in percentage units.
Can you suggest to me the appropriate OBIS code?

Profile picture for user Kurumi

Kurumi

4 years 11 months ago

Hi,

Hi,

It might be that there is no standard OBIS code for that. Then you need to use the manufacturer specific OBIS codes.

BR,
Mikko

Balveer Singh

4 years 11 months ago

Yes, Sir, Maybe, but while

Yes, Sir, Maybe, but while selecting the Manf. specific OBIS is there any restriction regarding percentage value?

Profile picture for user Kurumi

Kurumi

4 years 11 months ago

Hi,

Hi,

No. It's recommended that Manufacturer-specific values are not used, but if that is not in the standard you need to use it.

BR,
Mikko

Balveer Singh

4 years 11 months ago

OK Sir, Thanks for your

OK Sir, Thanks for your valuable time, the information was very helpful,
Thank you again.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin