By kaushik7119 , 17 December, 2020
Forums
General discussion

Hello, I have a meter which is of L&T make model no EM101+ and want to read the meter using RJ9 port but don't know the security level of the same I tried to read it with the optical port and have the SNRM request 7E A0 07 03 41 93 5A 64 7E, Could you help me to get to know the security level by SNRM.

thank you...

Profile picture for user Kurumi

Kurumi

5 years 5 months ago

Hi,

Hi,

There are several different security levels. You can try to connect without security first. You need to know the password if you want to connect using Low or High authentication.

You can try with GXDLMSDirector first. Select "Indian Standard" as a manufacturer and give it a try.

BR,
Mikko

BR,
Mikko

kaushik7119

5 years 5 months ago

Hello Mikko,

Hello Mikko,
I tried using the GXDLMSDirector but still no response using RJ9 port

how to solve this issue?

Profile picture for user Kurumi

Kurumi

5 years 5 months ago

Hi,

Hi,

There are three reasons for this.
#1. Your cables are not working. Check them.
#2. Serial port settings are not correct. Check the baud rate.
#3. Your server or client address is wrong. Check them from the meter documentation.
Because your meter is supporting Indian Standard 15959 I believe that this is not the reason.
#4 If you are using optical port try to change interface type from HDLC to HdlcWithModeE. In my mind, your meter is not support Mode E, but there might be different versions from the meter.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin