PRIME physical layer counters
Records corrupted bursts and queue overflows in the PRIME physical layer.
When to use it
For example, distinguish electrical noise from queue overload by comparing CRC errors with dropped data counts.
Attributes
1. Logical name
Identifies this object instance by its six-part OBIS code. Use it to distinguish this object from other objects of the same class.
2. CrcIncorrectCount
Counts received bursts whose CRC integrity check failed.
3. CrcFailedCount
Counts bursts whose CRC passed but whose physical header contained an invalid protocol value, revealing an error missed by the CRC.
4. TxDropCount
Counts occasions when the transmit queue was full and new or queued data had to be discarded.
5. RxDropCount
Counts occasions when the receive queue was full and newly received or queued data had to be discarded.