Image
By bahubali , 17 February, 2017

set a value

Forums
General discussion

Dear sir,

I want to set any value using guruxGXDLMS director …..but the problem is that only GET button is enable when we are connect to meter and make a connection …
Why the set option is not enable (means the key in the top of GXDLMS director window).
Please let me know Which changes are required to unable that set button?

Thanks and regards,
Bahubali

By Digambar Patil , 14 February, 2017

Events

Forums
General discussion

Dear sir,
we are using indian standard as a manufacturer for event reading.
while taking reading from the tool , response from the tool is accurately come as per DLMS standard.

There is a no problem with data response ....but the actual reading in the table shown in tool is not coming.
Total columns created are totaly blank..
what is the problem?....please suggest me..
Thanks in advance.
The response is as shown below.

By bahubali , 14 February, 2017

lowest level security

Forums
General discussion

Dear sir,

we are trying to use lowest level security with password "12345678" using indian standard as a manufacturer.
but the response from tool is as follows :
what is the problem?
The response is as per the blue book examples given.
thanks is advance.

By Farang1 , 20 January, 2017

EDMI MK 6 current kw display how to read

Forums
General discussion

I have a customer who rents his villa and needs to bill the renter for electrical usage.
Does the mk6 display acumulative kw usage so he can check kw usage when the tenant arrives and when they check out.
Sorry but we are just getting digital meters here in Thailand, and they are "magic" and no one will tell me anything about the meter or how to read it.
Thank You for any help or advice.
Harvey in Thailand

By atulsawant , 20 January, 2017

profile generic

Forums
General discussion

dear sir,

while reading objects from profile-generic class, the error is as follows ....what is that error and how can i remove it?

thanks in advance

By Sawgee , 19 January, 2017

Trying to Read Itron AEC6000

Forums
General discussion

don't know the setting to set

By atulsawant , 13 January, 2017

error

Forums
General discussion

Dear sir,

The tool shows following output:

By atulsawant , 12 January, 2017

OBIS code

Forums
General discussion

i am using your tool for testing of DLMS stack.
i am new user , i dont know the exact procedure for reading of data.
currently..i do the following setting:
manufacture : indian standard.
i am writing OBIS code in indian standard manufacturer.
then i am adding device through the file menu and connect the tool with the device ....it get connected..
but the OBIS code is not shown ...
my main que is that how to add the OBIS code ..

By Denis , 1 January, 2017

Problem with connection to ISKRA MT860 using serial communication

Forums
General discussion

Hello,

i need to read obis codes from an iskra mt860 but i can't connect to it because the gurux software doesn't receive reply from iskra. I'm trying to connect to iskra through serial communication RS485 on two wires, using a simple serial communication software if i send only one command: "/?!" or "/?serial_number!" i don't get reply but if i send two commands in sequence i get reply from the iskra, someone know what is the problem?

If i send one command:

/?! --> No reply

If i send two commands in sequence:

By Denis , 1 January, 2017

Obis codes for CEWE Prometer R

Forums
General discussion

Hello,

i need to read obis codes from two cewe prometers r, i created a new cewe manufacturer using landys&gyr manufacturer information, changing only the manufacturer id, i can connect to the cewe but i can get only two obis codes, date and manufacturer name... Someone know where i can find obis codes list for cewe prometer r?

The next week i will go back to the company where cewe prometers are installed and i will have one week to make it working...

I have a problem also with an ISKRA MT860, i will explain the problem in a new thread.

Pagination

  • Previous page
  • 63
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 06/15/2026 - 08:52
    gurux.dlms.c 9.0.2606.1501
  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin