Image
By Jeroen88 , 22 June, 2021

32 bit indices still not working

Forums
General discussion

Hi Mikko,

I still can not read the association object of my Iskra meter with DLMS.c because it is > 64k. You introduced #if defined(GX_DLMS_BYTE_BUFFER_SIZE_32) at several locations, but there are still 16 bit indices left, causing the problem to read the association object.

Examples are:
https://github.com/Gurux/GuruxDLMS.c/blob/1561c2e3cf5799d0952facf2ecdc8…

By aoudumbarpawar , 19 June, 2021

Queries regarding Invocation Counter

Forums
General discussion

Hii Mikko,
Sorry for bother you!!!

By ryuk , 16 June, 2021

How to read multiple meters(uses SN referencing) from a physical device?

Forums
General discussion

I came across a set up of few DLMS meters (Landis Gyr) which uses SN referencing where they have been configured within the same host.
In a single IP, we could see multiple meters are configured. Can anyone direct us on how to get the server addresses of configured meters so that I can read the objects of the same using below command.?

GuruxDlmsSample -r SN -c 16 -s [serverAddressOfMeter] -h [IP Address] -p [Port No]

By ikhwan_fn , 16 June, 2021

Itron ataris SL7000 can not get obis code

Forums
General discussion

Hi all

may be you can help me to read itron sl7000
i already can connect to meter
but i can not get obis code, the information was invalid

By aoudumbarpawar , 15 June, 2021

HLS WITH GMAC

Forums
General discussion

Hii Mikko,
I want to implement GMAC authentication.

Below are my some queries:
1. Is it compulsory to exchange client-servers system title in AARQ and AARE before pass 3 and 4
2. if suppose i am not included server systems title in AARE then what will happen.
3. How to authenticate the GMAC at server side which is received from the client
4. Which IC (invocation counter) must be used at server side during calculating GMAC

Also can share the frame log along with pass 1 ,2 ,3 ,4 (HDLC)

BR,
AP

By bryan.escobar , 9 June, 2021

I cannot read data from iskra MT880 with DLMS, python and serial ports.

Forums
General discussion

Hi,

I am trying to read data from the iskra MT880 with DLMS using python and serial port, but it has been impossible to extract the information.

When I run the code, I get the following response:

gurux_dlms version: 1.0.104
gurux_net version: 1.0.17
gurux_serial version: 1.0.15
Authentication: Authentication.NONE
ClientAddress: 0x10
ServerAddress: 0x4f

But then I get an error saying "Resource temporarily unavailable".

How can I fix this and be able to read the data from the meter?

By neut , 30 May, 2021

https://www.gurux.fi is not accisible

Forums
General discussion

https://www.gurux.fi is not accessible

"An error occurred during a connection to www.gurux.fi. PR_END_OF_FILE_ERROR"

And as a result the GXDLMSDirector cannot download manufacturer settings.

However Http is working. Is there a way to manually download and install the manufacturer settings?

By ramdev3108 , 29 May, 2021

Data parsing problem

Forums
General discussion

Hi Mikko,
we are facing encrypted data parsing problem with latest gurux tool, with previous version we don't have any problem both request and responses are got parsed, but in current version only requests are parsed not the responses, the tool library version also attached. Plz check the below given traces ,here the block-cipher key is 1111111111111111 (in ascii),

By Lotusv , 27 May, 2021

Gurux.DLMS.python Client Example

Forums
General discussion

I launched gurux.dlms.python/Gurux.DLMS.Client.Example.python
I have an Itron Actaris SL7000 meter connected via RS485 via an RS485-Net converter.
I connected, I read the registers, but the reading takes place from 8-12 attempts:

By Lotusv , 27 May, 2021

make Gurux.DLMS.cpp Client Example

Forums
General discussion

Tried to make Gurux.DLMS.cpp\GuruxDLMSClientExample

First the error appeared:

Pagination

  • Previous page
  • 19
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin