Hi, i want to ask regarding DLMS server.
i have successfully compile and run DLMS server example. i want to customize the connection parameters on Low authentication, such as client address, server address, logical address, password.
tell me please, how can i do that? inside GXDLMSBase.cpp, which part of the code deal with that? or is it in another source code? i tried finding 0x11 (default client address used to connect to the server) but no luck
As written in blue book 4.5.4 Special days table, methods insert/delete are optional. Gurux DLMS Director Add/Remove buttons in special days table objects unavailable for selection if methods insert/delete are not realized by meter manufacturer.
Is it possible to add Director functionality to modify Special Days table via ordinary set/get request?
Now I want to write to the meter objects. Is all the object attributes of a meter is writable? How to check it?
How to write meter objects using gurux python client?
When reading association view with GuruX.DLMS version 9.0.2411.2201, the list of attributes and methods where empty like this (for the clock object, but it applies to other objects as well):