  3. Help With Connection and Read With Landis+gyr E650 + CU-E22 Using Python

Help with connection and read with landis+gyr e650 + CU-E22 using python

By Juan Tobon , 2 March, 2026
Forums
DLMSDirector

Hi, this is Juan From colombia, for the last days i`ve been working with the landis+gyr e 650 Model:ZMD402 & the CU-E22.
I`m gonna talk you about what i wanna achieve, and maybe you could help me with that.
Ok, from the last days i've been trying to connec the landis from the CU to python, i already know which port i have to use and all the security information.
I try with wrapper and HDLC but i dont manage to make it work.
Usually the device open the tcp and arrq, after that he makes the request from tx-AARQ with the information bytes.
but when the device waits for the AARE it doesn't connect, it says that the device deny the connection.
and i wanna know if maybe you have encontered errors like this and what u usually do.
If you want maybe i could send you the python code, and all the information U may need.
grettings.

Profile picture for user Kurumi

Kurumi

5 months 1 week ago

Hi, There are differences…

Hi,

There are differences between L+G models but try this:

1. Select the Langis +Gyr as a manufacturer.
2. Make sure the "Logical Name referencing" is un checked.
3. Select authentication to None.
4. Establish the connection.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin