Image
By lara.wakim , 17 December, 2020

Questions and issues of the release "GXDLMSDirector 8.2.2012.1601"

Forums
General discussion

Hi Mikko,

We downloaded the latest release of the GXDLMSDirector. We have 3 points to highlight:

1- We noticed that you added the button reset for the object "OFDM PLC MAC network administration data" so we tried to trigger it, it is giving "Object reference not set to an instant of an object" not sure if it is a problem from the client or server side

By kaushik7119 , 17 December, 2020

SNRM

Forums
General discussion

Hello, I have a meter which is of L&T make model no EM101+ and want to read the meter using RJ9 port but don't know the security level of the same I tried to read it with the optical port and have the SNRM request 7E A0 07 03 41 93 5A 64 7E, Could you help me to get to know the security level by SNRM.

thank you...

By luca.fallabrino , 16 December, 2020

Trouble reading ISKRA MT880

Forums
General discussion

Hi, i need to read data from Iskra MT-880 using GSM connection.
I use a python command-line program which can read several models already (MT830, MT860, TE-851) as well as other manufacturers.
I can't get beyond the identification /?! command. Here are some example :

By lara.wakim , 15 December, 2020

Questions and issues of the release "gurux.dlms.c 20201214.1"

Forums
General discussion

Hi Mikko,

Hope everything is fine.

First, we want to thank for your hard work.

Second, we downloaded the latest release and we are starting the testing so we opened this discussion to report the bugs.

When we open the new project and build it, there is some errors mainly do to some missing casting (check the picture).

By Ashok_Chowdary , 11 December, 2020

Insufficient memory to continue the execution of the program

Forums
General discussion

Hi,
While I am reading Object in profile generic sometimes it is showing as "Insufficient memory to continue the execution of the program".
Why it is showing like this.

By Ashok_Chowdary , 11 December, 2020

MR and Firmware Associations not showing in the US Association

Forums
General discussion

Hi Mikko,
I given BASE(LowAssociation),BASE(FirmwareAssociation ), in the objects list of the US association.But those are not showing in the us association under ASSOCIATION_LOGICAL_NAME IC15.
similary SecuritySetup also given as like above in the objects list of Us Association those are showing in the US association under IC64.
please help me how to resolve this

By Ashok_Chowdary , 10 December, 2020

LLS_password change in US association

Forums
General discussion

Hi Mikko,
How we can change MR association password and Firmware Association password in US Association.
please help me.

By Ashok_Chowdary , 10 December, 2020

Problem with ActionSchedulepush

Forums
General discussion

Hi,
I am having a problem on gurux dlms director.
in the Action schedule push it is showing all scripts under script name. there only push related script has to be present.
please find that in attachment.

By pradson , 3 December, 2020

Convert octed date-time string to readable string.

Forums
General discussion

Hi,

I have a date-time and corresponding Octed string. How will I check that both are the same.
I mean, how will I convert octed string to readable format string?
Kindly suggest.

<!--2020-12-02 16:30:00-->
<OctetString Value="07E40C0207101E00FFFEB600" />

Thanks

By husainmalkani@… , 3 December, 2020

Not able to add the Object in Load Profile

Forums
General discussion

Hello,
I am trying to add the Object in the load profile, but after 11 objects added to the load profile, it is not allowing me to add any 12th object. by default, there are 6 objects in the Load profile. also, there is no logic in restricting the number of objects that can be added.

Pagination

  • Previous page
  • 30
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin