By Lotusv , 29 October, 2021

KeepAlive function in Python

Forums
General discussion

In the Python example
KeepAlive function not implemented for reading registers
No frame is sent

Send Keep Alive
Sent 7E A0 1A 02 23 03 32 75 62 E6 E6 00 C0 01 C1 00 0F 00 00 28 00 00 FF 01 00 F9 79 7E
Received 7E A0 1B 03 00 02 00 23 52 ED 70 E6 E7 00 C4 01 C1 00 09 06 00 00 28 00 00 FF B6 6E 7E

What function can you do this in Python?

By aoudumbarpawar , 22 October, 2021

Issue with export certificate using block transfer

Forums
General discussion

Dear sir,
I am trying to export the certificate using block transfer but gurux not handling the response
can please suggest the issue in my frame?

By bhatiasidharth.89 , 22 October, 2021

Getting Active power in kW

Forums
General discussion

Hi Mikko,

My custom meter is calculating the active power in kW but in the DLMS Blue book only W (enum 27) is defined. The requirement for us is to send the active power in kW only. How do I do that and make the units as kW?

Regards
Sidharth

By bhatiasidharth.89 , 19 October, 2021

OBIS codes for use case

Forums
General discussion

Hi Mikko,

I am adding DLMS compatibility over serial port to my custom single phase electricity meter and I needed some help in figuring out which OBIS codes would be appropriate for my use case. Here is my use case.

I measure the following meter parameters from the metering chip every 15 seconds and put them in an array:
1. Current RMS
2. Voltage RMS
3. Frequency
4. Wide band power
5. Fundamental power
6. Reactive power
7. Wide band energy
8. Fundamental energy
9. Reactive energy
10. Phase angle

By XYTeoh , 14 October, 2021

Landis+Gry E550 with 4G Modem

Forums
General discussion

Connecting Landis+Gry E550 to Gurux through 4G LTE network.
'Failed to receive reply from the device in given time' error occur

By jcf , 13 October, 2021

Javascript

Forums
General discussion

Hi all,

I'm investigating your solution for reading data from the meters in Portugal. The software we will use to read data from the meters only support javascript library. Do you have any libraries that we can use in our software ?

Thanks in advance,

Joana

By Lotusv , 8 October, 2021

Decode date-time from hex in LoadProfile

Forums
General discussion

I'm reading data from Load Profile (OBIS 0.0.99.1.0.255, Actaris Itron SL7000).
I get bytearray, convert in hex and get:
07E50A08FFFFFFFFFF8000FF

How can i convert this to human readable date/time format?
I didn’t find the functions or examples I needed.
in Python....
Help me, please.

By aoudumbarpawar , 5 October, 2021

Not able to write date time with new version

Forums
General discussion

Hii,

With updated version , not able to write date time in the meter.

BR,
AP

By Bhaumik , 4 October, 2021

Push Load Test

Forums
General discussion

Hi Mikko,

We have created one Push Listener service. In that, we are receiving push notifications from meters and do the parsing.

Now we want to do a load test for 1 Lakhs of the meter. Is it possible to send 1Lakhs of push data concurrently to service?

Can you please provide any suggestions on this?

By aoudumbarpawar , 4 October, 2021

Segmentation with Action request

Forums
General discussion

Hii,

I want to import the certificate in meter with action with block transfer method but gurux always requested with segmentation i.e 0xA8 event if meter negotiate conformance with action with block transfer.

Tx/Rx buffere size negotiated : 150 bytes
Negotiated conformance : GeneralBlockTransfer, BlockTransferWithGetOrRead, BlockTransferWithSetOrWrite, BlockTransferWithAction, DataNotification, Get, Set, SelectiveAccess, Action

Pagination

  • Previous page
  • 15
  • Next page
General discussion
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin