By Administrator , 26 May, 2025

addPort issue fixed if Context is used instead of Activity.

Project
Gurux.Serial.Android
Status
Closed (fixed)
Priority
Normal
Category
Bug report
By gxjason , 26 May, 2025

Access Violated Error Reading ProfileGeneric via Code, but Ok via Director (itron SL7000)

Forums
Gurux.Net

Dear Mikko,

Hi, I faced a strange issue.
I used Director and was able to connect with the meter (itron SL7000).
I can even read the profile generic of the Load Profile 1.
All good.
The params are as follows:

-h xxx.xxx.xxx.xxx -p 7623 -c 1 -s 145 -a Low -P XXXXXXXX -w 1 -f 128

However, when I use the API library via .net coding, I am unable to read the profile generic with the following error:
"Gurux.DLMS.GXDLMSException: Access Error : Device reports scope of access violated."

By Administrator , 26 May, 2025

gurux.dlms.c 9.0.2505.2601

The following important issues are resolved in this version:
A definition was added to enable multiple association views.

By Administrator , 26 May, 2025

A definition was added to enable multiple association views.

Project
gurux.dlms.c
Status
Closed (fixed)
Priority
Normal
Category
Feature request
By Basv@1 , 23 May, 2025

HDLC Adress resolver configuration

Forums
DLMSDirector

Hello. It is possible to add the option to select a number (address) а Logical server? According to the logs, addresses are scanned from logical address 0, but the energymeter can work as a logical device with address 1, etc.

By riteshP , 22 May, 2025

Reading all "Data" object type parameter together

Forums
Gurux DLMS for ANSI C

Hi,

I can able to read individual Data type object. Using following methods.
Client.init(true, 32, 1, DLMS_AUTHENTICATION_LOW, "xxxx", DLMS_INTERFACE_TYPE_HDLC);

cosem_init(BASE(ldn), DLMS_OBJECT_TYPE_DATA, "0.0.42.0.0.255");
com_read(BASE(ldn), 2);

By Somesh_8073 , 22 May, 2025

com_read getting failed for billing profile and instantaneous profile

Forums
Gurux.DLMS

hello,
below code is for to read instantaneous and billing profile - - >

void
read_meter_instantaneous_profile()
{
gxProfileGeneric profile;
char * data = NULL;
cosem_init(&profile.base, DLMS_OBJECT_TYPE_PROFILE_GENERIC, "1.0.94.91.0.255");

com_read(&profile.base, 2);

/* Read rows by entry */
com_readRowsByEntry(&profile, 1, 2);

By Mahaveer , 21 May, 2025

Simulator connection closed

Forums
Gurux.Net

Hi,

I have created 100 simulator in Gurux.DLMS.Simulator.Net project with start port 1000 to 1099, and it's working fine but randomly closes connection for some ports when I connect it from code or director tool.

Can you please suggest me the solution, as per my requirement it should always connect and response data as it is running in my local system.

By atuldd , 21 May, 2025

Regarding the dlms android project

Forums
Gurux DLMS for Android

getting invalid system title in main fragment
though i am selecting general meter settings

now in the 2.0.15 there is an optional fragment called security where the client system title option provided

i need the general meter setting which is getting affected with invalid system title

and open is not happening which was happening in 2.0.14

By Jimmy , 20 May, 2025

Image Transfer - Verification with Temporary Failure

Project
GXDLMSDirector
Status
Active

Hi, Mikko,

I'm using Director to upgrade firmware of the meter. The block has been transferred successfully into the meter. But during image verification process, since it will take some time to verify, the meter responded with "temporary failure" asking Director to wait and get image_transfer_status again until the verification process finished(Fig.11 in Blue Book). But Director prompts the "temporary failure" and then activation later cannot be taken effect, so the process finally failed. It is suggested to make a update on Director to accept the "temporary failure" response and proceed with process to succeed in the process finally. Thank you!

Best Regards,
Jimmy

Priority
Critical
Category
Support request

Sajjad khan pathan

1 year 4 months ago

Hi, I'm also reporting the…

Hi,

I'm also reporting the same issue under this topic.

Gurux repeatedly performs the Image_Verify action instead of proceeding to read the Image Transfer Status.

As per – Image transfer process flow chart - in the DLMS Blue Book, client should check Image Transfer Status in Loop upon receiving temporary failure.

Pagination

  • First page
  • Previous page
  • …
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • …
  • Next page
  • Last page

Pagination

  • First page
  • Previous page
  • …
  • Page 52
  • Page 53
  • Page 54
  • Page 55
  • Page 56
  • Page 57
  • Page 58
  • Page 59
  • Page 60
  • …
  • Next page
  • Last page
  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 10/13/2026 - 12:00
    gurux.dlms.java 4.0.97
  • Tue, 09/22/2026 - 14:02
    Gurux.DLMS.Net 9.0.2609.2201
  • Mon, 09/21/2026 - 10:18
    Gurux.DLMS.Net 9.0.2609.2101
  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202

New forum topics

  • Need RJ45 pin configuration for Saral 300 and Saral 305 Secure meters
  • Query Regarding Class 63 Status Mapping Support in Gurux DLMS Python
  • Inhemeter
  • DLMS Server - Profile Generic - can't add too many items to profile generic capture object - how to set maximum profile entries
  • HDLC Frames sequencing
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin