Hello Mikko,

I've used DLMS translator a lot before and this is the first time when result is not ok. Could you please take a look - is it a meter communication problem or something else?
Translator gives me a strange result while decoding following data exchange:

13450 15:56:56:800 TX:0.1.25.9.0.255 attr = 2
TX: 7E-A0-1A-02-23-61-14-A4-70-E6-E6-00-C0-01-C1-00-28-00-01-19-09-00-FF-02-00-00-40-7E

13451 15:56:56:979 RX: 7E-A8-7E-61-02-23-70-65-68-E6-E7-00-C4-01-C1-00-01-05-02-06-12-00-01-09-06-00-00-2A-00-00-FF-0F-02-12-00-00-02-02-16-00-00-01-00-02-06-12-00-03-09-06-01-00-01-08-00-FF-0F-02-12-00-00-02-02-16-00-00-01-00-02-06-12-00-03-09-06-01-00-02-08-00-FF-0F-02-12-00-00-02-02-16-00-00-01-00-02-06-12-00-03-09-06-01-00-03-08-00-FF-0F-02-12-00-00-02-02-16-00-00-01-00-02-06-12-00-03-09-06-B5-6E-7E

13452 15:56:56:980 TX:7E-A0-08-02-23-61-31-C3-A4-7E

13453 15:56:57:033 RX: 7E-A0-1C-61-02-23-72-14-DD-01-00-04-08-00-FF-0F-02-12-00-00-02-02-16-00-00-01-00-68-1C-7E

13454 15:56:57:047 TX:WriteRequest data.
TX: 7E-A8-8A-02-23-61-56-FF-0E-E6-E6-00-C1-01-C1-00-28-00-01-19-09-00-FF-02-00-01-05-02-06-12-00-01-09-06-00-00-2A-00-00-FF-0F-02-12-00-00-02-02-16-00-00-01-00-02-06-12-00-03-09-06-01-00-01-08-00-FF-0F-02-12-00-00-02-02-16-00-00-01-00-02-06-12-00-03-09-06-01-00-02-08-00-FF-0F-02-12-00-00-02-02-16-00-00-01-00-02-06-12-00-03-09-06-01-00-03-08-00-FF-0F-02-12-00-00-02-02-16-00-00-01-00-02-06-12-00-03-09-06-01-00-04-CE-DC-7E

13455 15:56:57:206 RX: 7E-A0-08-61-02-23-91-D1-91-7E

13456 15:56:57:216 TX:WriteRequest data.
TX: 7E-A0-19-02-23-61-58-00-E5-08-00-FF-0F-02-12-00-00-02-02-16-00-00-01-00-61-E6-7E

13457 15:56:57:268 RX: 7E-A0-11-61-02-23-B4-5A-02-E6-E7-00-C5-01-C1-48-1C-47-7E

Looking at translate result In output window, I see two frames with a very long "Value" attribute
<SourceAddress Value="91" />
<FrameType Value="70" />
<NextFrame Value="C401C10001050206120001090600002A0000FF0F0212000002021600000100020612000309060100010800FF0F0212000002021600000100020612000309060100020800FF0F0212000002021600000100020612000309060100030800FF0F021200000202160000010002061200030906" />

Best regards, Andrew

Profile picture for user Kurumi

Kurumi

1 year 4 months ago

Hi Andrew, All the data does…

Hi Andrew,

All the data does not fit into one frame and for that reason, the data can't be converted to XML. Try to select "View" and "Complete PDU". Now you can see the XML.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin