Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Scaler of Obis Doesn't Work For Month Bill Profile, But Works For Instantaneous Profile

Scaler of obis doesn't work for Month bill Profile, but works for Instantaneous Profile

By mightyChamp , 18 October, 2023
Forums
DLMSDirector

Greetings,

I'm currently using Gurux Director Software to read data from a DLMS Meter. I've successfully added the meter and established a connection to it. After connecting, I've read the Associate View and Scaler (asked by Software on First Connect).

Next, I've proceeded to read the Instantaneous Profile, where I noticed that the Power Factor (PF) value is correctly displayed as 1. However, when I read the Month Bill Profile, the PF value appears as 100, indicating that it's not divided by the scaler.

This same issue occurs in Android library.

I'm seeking assistance to understand why this discrepancy occurs and how I can resolve this issue. Your guidance would be greatly appreciated.

Thank you.

Profile picture for user Kurumi

Kurumi

2 years 7 months ago

Hi, I don't know what meter…

Hi,

I don't know what meter you are using, but it might be that your Bill Profile scalers are not set to register objects and you need to read the scaler profile (1.0.94.91.5.255) where this information can be found.

GXDLMSDirector can't handle the scaler profile at the moment.

BR,

Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin