Hi Mikko,

I don't understant why I'm not able to write a new value (ex: 0.0.22.0.0.255) for HDLC destination address in cosem objects 0.0.25.9.0.255 and 0.4.25.9.0.255. There is no problem when we set an IPV6 address with service=Tcp.
The meter response says "Hardware fault" :

11:03:02
<!-- Invocation Counter: 2238247983 -->
<!-- Decrypt data: C1 01 C1 00 28 00 04 19 09 00 FF 03 00 02 03 16 05 09 06 00 00 16 00 00 FF 16 00
<SetRequest>
<SetRequestNormal>
# Priority: High, ServiceClass: Confirmed, Invoke ID: 1
<InvokeIdAndPriority Value="C1" />
<AttributeDescriptor>
# PushSetup
<ClassId Value="0028" />
# 0.4.25.9.0.255
<InstanceId Value="0004190900FF" />
# Send Destination And Method
<AttributeId Value="03" />
</AttributeDescriptor>
<Value>
<Structure Qty="03" >
<Enum Value="05" />
# 0.0.22.0.0.255
<OctetString Value="0000160000FF" />
<Enum Value="00" />
</Structure>
</Value>
</SetRequestNormal>
</SetRequest>
-->
<glo_SetRequest Value="308568F42F55082A693249D93F81F86952F3FA8E45C1E1402FED49973DE0A9DE62B3C58F1719B9460A6B3F0A" />

11:03:02
<!-- Invocation Counter: 931157354 -->
<!-- Decrypt data: C5 01 C1 01 0D
<SetResponse>
<SetResponseNormal>
# Priority: High, ServiceClass: Confirmed, Invoke ID: 1
<InvokeIdAndPriority Value="C1" />
<Result Value="HardwareFault" />
</SetResponseNormal>
</SetResponse>
-->
<glo_SetResponse Value="303780556AF3898061C24700E50051A256FCDD9714B3" />

Profile picture for user Kurumi

Kurumi

3 years 6 months ago

Hi,

Hi,

The content of the data seems correct. You need to ask the meter manufacturer what they are expecting and is the meter supporting HDLC push messages.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin