By sesaomz , 29 June, 2022
Forums
DLMSDirector

Hi,
I am connecting gxdlms director to one meter propietary (developed by us).
We have defined one obis with write and read permission but we are still getting "acces error: device reports read-write denied" and we don't know why. This is the frame and the response:

<WRAPPER len="14" >
<TargetAddress Value="1" />
<SourceAddress Value="1" />
<PDU>
<SetRequest>
<SetRequestNormal>
<!-- Priority: High, ServiceClass: Confirmed, Invoke ID: 1 -->
<InvokeIdAndPriority Value="C1" />
<AttributeDescriptor>
<!-- Data -->
<ClassId Value="0001" />
<!-- 0.0.96.1.10.255 -->
<InstanceId Value="000060010AFF" />
<!-- Value -->
<AttributeId Value="02" />
</AttributeDescriptor>
<Value>
<!-- 00 01 -->
<OctetString Value="3030203031" />
</Value>
</SetRequestNormal>
</SetRequest>
</PDU>
</WRAPPER>

<WRAPPER len="4" >
<TargetAddress Value="1" />
<SourceAddress Value="1" />
<PDU>
<SetResponse>
<SetResponseNormal>
<!-- Priority: High, ServiceClass: Confirmed, Invoke ID: 1 -->
<InvokeIdAndPriority Value="C1" />
<Result Value="ReadWriteDenied" />
</SetResponseNormal>
</SetResponse>
</PDU>
</WRAPPER>

What are we doing wrong?
thanks.

Image
Profile picture for user Kurumi

Kurumi

4 years ago

Hi,

Hi,

It looks like everything is correct. Read the value and try to write the same value back. The meter returns a clear error. You need to check that this value is writable and data type is the same on read and write.

BR,
Mikko

sesaomz

4 years ago

Thanks. I will check that.

Thanks. I will check that.
Regards.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200
  • Mon, 06/15/2026 - 08:52
    gurux.dlms.c 9.0.2606.1501

New forum topics

  • Service not known error on gprs communication
  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
More

Who's new

  • ksFhuuipOxKrxk…
  • sherylrk3
  • OLaneHycle
  • LxfgLnoisbruoL…
  • SunbetLith
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin