Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Changing Server Address

Changing server address

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By kristupas , 11 February, 2022
Forums
Gurux.DLMS

Hello,

I have few questions:

1) Is it possible to change meter's server address using gurux cpp library?
2) How does 5-pass authentication works? I am reading Shenzhen CLOU electronics meter documentation and they state that they use HLS-5 pass authentication with challenge mechanism. Is that GMAC authentication? If so, what kind of data do we need to know in order to connect to establish secured connection. Authentication, blockCipherKeys?

Profile picture for user Kurumi

Kurumi

4 years 5 months ago

Hi,

Hi,

1. It depends on the meter and communication channel. If you are using HDLC you can try changing the Device address.
http://www.gurux.fi/Gurux.DLMS.Objects.GXDLMSIecHdlcSetup

2. HLS-5 is using GMAC. You need to know authentication and block cipher keys to establish the connection.

BR,
Mikko

kristupas

4 years 5 months ago

Thanks for the answers. These

Thanks for the answers. These keys should be provided by the manufacturer, right?

Profile picture for user Kurumi

Kurumi

4 years 5 months ago

Hi,

Hi,

Yes, The manufacturer is the only one who knows those keys.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • BaEdhlfwwvUqFMkOYk
  • CrzONrPdvkWUif…
  • kra4026
  • HilipLot
  • NithnCXPiBJHVG…
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin