Hello,

I have few questions:

1) Is it possible to change meter's server address using gurux cpp library?
2) How does 5-pass authentication works? I am reading Shenzhen CLOU electronics meter documentation and they state that they use HLS-5 pass authentication with challenge mechanism. Is that GMAC authentication? If so, what kind of data do we need to know in order to connect to establish secured connection. Authentication, blockCipherKeys?

Profile picture for user Kurumi

Kurumi

4 years 7 months ago

Hi,

Hi,

1. It depends on the meter and communication channel. If you are using HDLC you can try changing the Device address.
http://www.gurux.fi/Gurux.DLMS.Objects.GXDLMSIecHdlcSetup

2. HLS-5 is using GMAC. You need to know authentication and block cipher keys to establish the connection.

BR,
Mikko

kristupas

4 years 7 months ago

Thanks for the answers. These

Thanks for the answers. These keys should be provided by the manufacturer, right?

Profile picture for user Kurumi

Kurumi

4 years 7 months ago

Hi,

Hi,

Yes, The manufacturer is the only one who knows those keys.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • Anaglyfos Trading CC
  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin