Dear Mikko,

CTT Test case also passed Or not

1.test case failed while proposed-dlms-version-number = 7, CTT VERSION 106 AND 107

2.General Block Transfer(GBT)(In US Association) not implemented in their GURUX Stack as memory constraint might exist

Profile picture for user Kurumi

Kurumi

5 years 4 months ago

Dear,

Dear,

1 proposed-dlms-version-number = 7, release 107.
0'35.884 VERDICT: 2: proposed-dlms-version-number = 7 PASSED

This test is using 4 bytes addressing. Try to connect to the meter with GXDLMSDirector. I checked the values that you are using in the _CTI file. Set physical address to 255 and logical address to 1. If this fails, modify svr_isTarget for your needs.

2. GBT is using a lot of memory if ciphering is used because all data must be read to the memory before data is encrypted and sent to the client. This is a killer because ciphering is applied to the complete APDU and then ciphered data is sent as data blocks. Read more from the Green Book: 9.1.4.4.5 Transferring long messages

This is a big problem when you want to read thousands of rows from the profile generic. I believe that there is not enough memory in any consumer meter to do this.

BR,
Mikko

rajacms

5 years 4 months ago

Dear Mikko,

Dear Mikko,

how to test proposed-dlms-version-number = 7, release 107.
and in server.c why need following code....
else if (ret == 0 && result == DLMS_ASSOCIATION_RESULT_ACCEPTED)
{
if (settings->base.dlmsVersionNumber < 6)
{

Profile picture for user Kurumi

Kurumi

5 years 4 months ago

Hi,

Hi,

Please, don't modify the framework. Make all the changes for the main application.
That code will handle the previous test for proposed-dlms-version-number = 5.

Can you connect to the meter using GXLMSDirector if you set the Physical address to 256 and the logical address to 1. I believe that is the problem.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • CTKNhZElptjSlOrpkXl
  • YCbccqfLGRMnlCWoJhXP
  • Malcolmactig
  • mhliang
  • Kevinmug
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin