Skip to main content
Home
for DLMS smart meters
Open source solutions for DLMS smart metering

Main navigation

  • Home
  • Products
  • About us
  • Open Source
  • Community
  • Forum
  • Downloads
User account menu
  • Log in

Breadcrumb

  1. Home
  2. Forums
  3. Proposed-dlms-version-number = 7

proposed-dlms-version-number = 7

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By rajacms , 6 March, 2021
Forums
General discussion

Dear Mikko,

CTT Test case also passed Or not

1.test case failed while proposed-dlms-version-number = 7, CTT VERSION 106 AND 107

2.General Block Transfer(GBT)(In US Association) not implemented in their GURUX Stack as memory constraint might exist

Profile picture for user Kurumi

Kurumi

5 years 8 months ago

Dear,

Dear,

1 proposed-dlms-version-number = 7, release 107.
0'35.884 VERDICT: 2: proposed-dlms-version-number = 7 PASSED

This test is using 4 bytes addressing. Try to connect to the meter with GXDLMSDirector. I checked the values that you are using in the _CTI file. Set physical address to 255 and logical address to 1. If this fails, modify svr_isTarget for your needs.

2. GBT is using a lot of memory if ciphering is used because all data must be read to the memory before data is encrypted and sent to the client. This is a killer because ciphering is applied to the complete APDU and then ciphered data is sent as data blocks. Read more from the Green Book: 9.1.4.4.5 Transferring long messages