  3. Save To File New Capture Data (profile Generic)

Save to file new capture data (profile generic)

Forum Rules

Before commenting read Forum rules

Don't comment the topic if you have a new question.

You can create a new topic selecting correct category from Gurux Forum and then create a new topic selecting "New Topic" from the top left.

By lara.wakim , 16 July, 2020
Forums
General discussion

Hi,

In the captureEventLog() and handleLoadProfileActions() functions of the server example 2, the capture action of the profile generic is reading each time all the saving data in the file then append the new data to the file then write all the data again including the new one instead of appending directly the new data to the file at the correct row index.

Is it any specific explanation to that way of capturing? Can we instead seeking to the specific row index and write directly the new data or there any problem?

Best Regards,

Lara Wakim

Profile picture for user Kurumi

Kurumi

6 years 2 months ago

Hi,

Hi,

The reason why all the data is read and then saved to the file is that direct writing was causing problems with some PCs. This approach is more effective in different environments. You can try direct writing.

BR,
Mikko

lara.wakim

6 years 2 months ago

Hi,

Hi,

We are trying the direct writing and it seems to work just fine.

Thank you.

Best Regards,

Lara Wakim

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More

Who's new

  • cyby
  • Metin Onan
  • ssv007
  • 3nzol3dur
  • dw772
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin