Hi,

In the captureEventLog() and handleLoadProfileActions() functions of the server example 2, the capture action of the profile generic is reading each time all the saving data in the file then append the new data to the file then write all the data again including the new one instead of appending directly the new data to the file at the correct row index.

Is it any specific explanation to that way of capturing? Can we instead seeking to the specific row index and write directly the new data or there any problem?

Best Regards,

Lara Wakim

Profile picture for user Kurumi

Kurumi

6 years ago

Hi,

Hi,

The reason why all the data is read and then saved to the file is that direct writing was causing problems with some PCs. This approach is more effective in different environments. You can try direct writing.

BR,
Mikko

lara.wakim

6 years ago

Hi,

Hi,

We are trying the direct writing and it seems to work just fine.

Thank you.

Best Regards,

Lara Wakim

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701
  • Thu, 07/23/2026 - 16:19
    gurux.dlms.java 4.0.96
  • Thu, 07/09/2026 - 14:34
    Gurux.DLMS.Python 1.0.201
  • Fri, 06/26/2026 - 16:32
    Gurux.Service 3.0.2606.2601
  • Wed, 06/24/2026 - 08:36
    Gurux.DLMS.Python 1.0.200

New forum topics

  • Service not known error on gprs communication
  • Help Needed: Interfacing Saral 100 Energy Meter with Microcontroller via RS232
  • Connecting Meter to Agent via serial
  • Reading block profile with Compact array
  • DLMS server - serving multiple similar datasets gathered from multiple meters across distinct logical addresses
More

Who's new

  • CTKNhZElptjSlOrpkXl
  • YCbccqfLGRMnlCWoJhXP
  • Malcolmactig
  • mhliang
  • Kevinmug
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin