Hi.
As a Application (client by DLMS) know what devices (server by DLMS) are connected, if the initiator connection is a device with a built-in GSM modem mode GPRS (powered by lithium battery) with a dynamic IP address (protocol TCP/IPv4)?
In my opinion, the solution may be as follows:
1. After tcp_established the first request from the “Data Collection” SERVER (client by DLMS) SNRM should be empty (ID server by DLMS) (No-station - 0 or All-station (broadcast)-0x3FFF);
2. From the device as CLIENT (server by DLMS) must sent to the identification packet with address for next step.
Or is there another solution?
Thanks.

Profile picture for user Kurumi

Kurumi

11 years 2 months ago

Correction previous question

Hi,

I believe that I have answered for your questions here:
http://www.gurux.fi/node/11177

Sorry for a delay.

BR,

Mikko

iMeter

11 years 2 months ago

Result investigations

I answer to myself
1. First step: request by Client (Version-uint16, Src-uint16, Dst-uint16, Length-uint16: – 000100010001xxxxAARQ);
2. Second step: Get SAP Assignment;
3. Treed step: Disconnect:
4. Send AARQ with Serial Number (00010001xxxxyyyyAARQ).

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Tue, 06/09/2026 - 11:16
    gurux.dlms.java 4.0.95
  • Tue, 06/09/2026 - 10:03
    Gurux.DLMS.Python 1.0.199
  • Mon, 06/08/2026 - 13:39
    gurux.dlms.cpp 9.0.2606.0801
  • Mon, 06/01/2026 - 10:15
    gurux.dlms.cpp 9.0.2606.0101
  • Thu, 05/28/2026 - 16:06
    gurux.dlms.java 4.0.94

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More

Who's new

  • Tuanhgg
  • Adel
  • charnon
  • Paddles
  • Miguel Ángel
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin