  3. Gurux.dlms.GXDLMSException: Invalid Exception.

gurux.dlms.GXDLMSException: Invalid Exception.

By Tsveten.Kavrakov , 20 February, 2025
Forums
Gurux.DLMS

when i call client.parseUAResponse(response); with response "7EA0230300023E2F73D577818014050200F8060200F807040000000108040000000158717E" it rises Invalid exception, but I copied this response from factory application log and this i valid. What is wrong ?

Profile picture for user Kurumi

Kurumi

1 year 6 months ago

Hi, What programming…

Hi,

What programming language are you using?

BR,
Mikko

Tsveten.Kavrakov

1 year 6 months ago

Hi I'm using Java

Hi
I'm using Java

Profile picture for user Kurumi

Kurumi

1 year 6 months ago

Hi, Did you convert hex log…

Hi,

Did you convert hex log hex data data to bytearray?
I believe that one of your settings is different that what the meter uses.
With GXDLMSTranslator you can convert data to XML string like this:

GXDLMSTranslator t = new GXDLMSTranslator();
GXByteBuffer bb = new GXByteBuffer();
bb.setHexString("7EA0230300023E2F73D577818014050200F8060200F807040000000108040000000158717E");
System.out.println(t.messageToXml(bb));

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 08/26/2026 - 09:04
    Gurux.DLMS.Python 1.0.203
  • Mon, 08/17/2026 - 11:28
    Gurux.DLMS.Python 1.0.202
  • Mon, 08/17/2026 - 09:47
    gurux.dlms.cpp 9.0.2608.1701
  • Mon, 08/17/2026 - 09:25
    gurux.dlms.c 9.0.2608.1701
  • Mon, 07/27/2026 - 12:37
    gurux.dlms.cpp 9.0.2607.2701

New forum topics

  • Security vulnerability report — request for a private contact (GuruxDLMS.c / ANSI C)
  • Topic: Insufficient Memory Error When Reading Class 7 Profile Generic Objects
  • SN ReadResponse returns all-null values when response spans multiple HDLC frames
  • Gurux.Serial.Android 3.0.6 – CH340 (HL-340) USB-Serial Adapter Not Working,
  • Trying to talk to a L&G E360 meter (Using Python Gurux)
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin